标称 截面 mm2绝缘 标称 厚度 mm电缆最大 外径mm参  考  重  量 ㎏/km20℃导体直流电阻 最大值Ω/km允许载流量A
空气敷设土壤敷设
非铠装铠装VVVLVVYVLYVV22VLV22VV23VLV23
1.50.812.215.7148-123-----12.1-15-22-
2.50.813.216.7190142163115----7.4112.119152923
41.015.218.82661922331594443694013264.617.4126203830
61.016.420.03402303041946314204853743.084.6132264739
101.019.523.05103224702827375486864791.833.0846356550
161.022.025.57184206713739726739146151.151.9160478465
251.226.129.610705971013540137289813048300.7271.20776011084
351.228.832.3139774113336771729107316519950.5240.8689574130100
501.428.233.51755826168976024051476231813890.3870.64111590155120
701.431.937.023741073229699530874786298516840.2680.443145115195150
951.636.441.6318014143085131940032238388321180.1930.32185140230185
1201.640.245.7396117313852162248872657475225220.1530.253210165260205
1501.845.150.9493221454806201959953208584330560.1240.206245190300230
1852.050.156.0607026325918248072623824707936410.09910.164280215335260
2402.255.961.8778633267601314091104650889944390.07540.125335260390300