配色: 字号:
电缆主绝缘定位
2015-12-30 | 阅:  转:  |  分享 
  
HDBM-30/4cablefaultlocationpower

1.Generalintroduction

Itisadvancedequipmentascablefaultlocationpower.Thepulseoutputhas

twomode:singleoutput,andperiodicaloutput.

Function:

DCvoltagetest

Strongburningfunction,withinshorttimeitburnsbreakdownpoint,andlowers

resistanceatbreakdownpoint.



2.Technicaldata

outputvoltage(negative)0~30kVcontinuousregulation

Maximumburningpower:800W

Dischargecapacitor:4microfarad

Singledischargeenergy1800J

volume:42cm′42cm′80cm

Weight:90kg

workingpower220V±15%,1kVA



3.Operationinstruction

DCvoltagewithstand

Setfunctionswitchto“DChighvoltage”,andsetoutputDChighvoltage.

Singledischarge

Setfunctionswitchto“HVpulse”,modeas“single”andpress“pulsetriggering”

Andsystemwillmakesinglesetdischarge,breakdownthecablefault,and

formsabigcurrentpulse.

Periodicaldischarge

Functionswitchat“Highvoltagepulse”,modeas“period”,instrumentwill

dischargeperiodically.

Faulturgentstop

Duringtest,ifthereisnoabnormality,pressredbutton“switchoff”,and

instrumentwillturnoffpower,anddischargeautomaticallytoHVcapacitance

HDBM-30/4cablefaultlocationpower

andtestedobject.

Limitswitchfunction

Thereisstatusandpositioncheckatfunctionswitchpart.

HVcanstartonlywhenswitchispressed,andHVregulationbuttonisrotated

tobottomanti-clockwise.



4.supplyrange

4.1HDBM-30/4cablefaultlocationpower1set

4.2HVoutputcable1pc

4.3dischargerod1pc

4.4specialgroundingwire1pc

4.5powerwire1pc

4.6sparefuse(10A,6×30)2pcs

4.7usersmanual1pc

4.8certificate1set

4.9HDBM-30/4cablefaultlocationpowerusers’manual



5.Panel

5.1frontpanel

HDBM-30/4cablefaultlocationpower



HDBM-30/4frontpanel

Note:thepanelwillbeEnglishforforeigncustomer

NO1HVon;NO2currentmeter;NO3poweroff

NO4poweron;NO5voltmeter;NO6modeswitch

NO7pulsetrigger;NO8functionswitch;NO9HVregulationbutton

1.HVon:whenHVregulationbutton(No9)isbacktozero,andfunction

switch(NO8)ispressedatDChighvoltage,HVpulse,andstablearc,

pressHVswitch(NO1),andthenHVoutputpowerison,atthesametime,

HVonbuttonisoff,andpowerindicationlampon.

2.currentmeter:displayoutputcurrentwithrangeof100mA

3.poweroff:atemergency,pressthisbutton,andinnerworkpowerisoff,and

dischargedeviceautomaticallyconnectstoground.

4.poweron:whenkeyswitchisaton,poweronbuttonwilllight,pressthe

button,andworkpowerisconnected.

5.voltmeter:displayoutputvoltage,measurerangeis30kV.

6.modeswitch:workwithfunctionswitch,chooseHVoutputmode,singleor

HDBM-30/4cablefaultlocationpower

periodicalpulseoutput

7.pulsetrigger:whenmodeswitchedtosingle,presspulsetrigger,and

instrumentwilldischargeforonetime.Ittakesthreesecondstocharge

capacitor.Afterelectricityisfull,instrumentcantriggeragain.

8.functionswitch:therearefourgears,stablearc,lowvoltagepulse,DChigh

voltageandhighvoltagepulse.

9.HVregulationbutton:itregulatesoutputvoltage,andwithzerostart

function



5.2HDBM-30/4backpanel



Note:thepanelwillbeEnglishforforeigncustomer

1.Fusebase:innerΦ6×3010Afusetube

2.220VACpowersocket:outerconnectedwith220VACpower

3.Keyswitch

4.220VACpowersocket:whenconnectedwithHDTDRswitch.

5.Pulsecurrent:pulsecurrentcouplerinside,whosesignaloutputpulse

currentwaveform.

6.Stablearc:thesignaloutputwaveformofoutputarc.



6.Keyswitch

Atthebacksidethereisapowerswitch,whichcantakeitoffseparately.



7.Safety

7.1powerconnection

HDBM-30/4cablefaultlocationpower

Poweron④greenindicationlampgreenmeanspowerconnectionisOK.Plug

cablewire,andopenkeyswitchto“on”potion,andthenpoweron④islighting.

Ifitdoesnot,pleasecheckpowersocketorpowerline,whethertheycontacts

well.

7.2preparations

Presspoweron④,HVon①redlampon,connect220VACpower,andpower

off③doesnotlight.Atthistime,HVisnoton,andoutputisatshortcircuit

status.

7.3Starthighvoltage

PressHVon①,whenHVon①redlampisoff,poweroff③redlampison,

HVisstarted.Pleasenote:

Ifpresspoweroff③,andredlightofpoweroffisstillon,thatmean,HVisstill

effective.Pleasetakecarethatthereisstillhighvoltage.

7.4.safetyrequirement

Otherequipmentwhichisnotprotectedshallnotcontactwiththisequipment.

7.5safetyarea

Whentheequipmentisworkingthereshallbeaalarmingpanel,indicatingHV

danger.

7.6emergencyswitch

AtthebacksideofHDBM,thereisapoweroffemergencybutton.Ifthereis

anyabnormality,pressHVoff,andequipmentwillswitchoffpower.Auto

dischargedevicewillautomaticallydischargeHVandtestedobject,andmake

earthing.



8.Operationinstruction

8.1HDBMhasthreeoutputmodes:

DChighvoltage,HVpulseandstablearc(lowvoltagepulsewithstablearc).

Inalloutputmodes,voltageisoutputthroughHVcable,whichisputatthe

backpanel.Pleasenote,HVoutputcableinsertandoffshallbedonewhen

powerisnotconnected,andwhenthereisnovoltage(voltmeteris0.).The

HDBM-30/4cablefaultlocationpower

groundingshallbereliable.



HDBM-30/4HVoutputsocketandoutercovergroundingbase



8.2noticepoint

Beforeuseit,pleasemakesure:

Equipmentisreliablyconnectedtoearth

HVoutputcableandequipmentarereliablyconnected.

HVoutputcableandtestedobjectisreliablyconnected

Putalarmboardatthecablefarend,andmakeafenceoralarmingline.

8.3grounding

Beforeuseit,pleaseensurereliablegrounding.Theclipofgroundinglineshall

contactwithcleanmetal.Ifthereisrusty,pleaseclearitoff,andthenconnect

groundingwire.

8.4.HVoutputcableconnectionwithequipment

HVoutputcableoneterminalplugstoHVsocket,andtightthescrewonthe

socket.



HDBM-30/4cablefaultlocationpower

Redcliptocoaxialcablecore,blackclipandgroundingcliptoshieldinglayer

ofcoaxialcable.

8.5HVoutputcableandtestedcable.

Beforeconnection,takedischargerodtodischargethefaultcable,andthen

connectthefaultcabletogroundingwire,ensurethatfaultcableisfully

discharged,andthenstartwireconnection.

Cablecoreandshieldingfault:redcliptofaultcablecore,blackclipto

shielding,groundingcliptoearth.

Cablecoreandcorefault:redtocablecore,blackcliptoanotherphasecore,

andgroundingclipconnecttogroundreliably.

Coreandgroundfault:redtofaultcablecore,blackcliptoground,and

groundingcliptogroundreliably.

Coversafetygrounding:connectittogroundnearbytheequipment,tryto

makedistancefromredclipandgroundingclip.

Afterconnectionisover,takeoffthegroundingwireatfaultcable.

8.6functionswitchoperation

(a)functionswitchnormal(b)functionswitchfullyopen



Operation:raiseitathangingstatus,rotateittocorrespondingfunction,and

pressit.

8.7Dischargerod

HDBM-30/4cablefaultlocationpower



9.DChighvoltagetest

DCvoltagewithstandismainlyusedforresiduevoltage,DCvoltagewithstand

test,orburningpurposeafterloweringcablefaultpointresistance.

Operationindication:thepanelhasthreebuttons:pressthebuttonwhichis

lampon.

1.start,asto8.3,8.4,8.5.Takedischargerod,makethetestedobject

discharge.Connectagoodgroundingwiretotestedobject.Connectwell

theHVoutputwire,groundingwire,anddischargerod.

2.RotatethekeyswitchtoDChighvoltagegear,pressit.

3.Insertkey,rotateittoopen,andthenpoweronlamplights.

4.Presspoweron,greenlampisoff,HVonlights,andequipmentis

connectedtoworkpower.

5.Anti-clockwiseregulatethevoltagebutton,pressHVon,andHVonbuttonis

off.Powerofflampison.HVisstarted.

6.Accordingtotestrequirement,setoutputvoltage.Theequipmentdoesnot

haveovercurrentprotection.Testobjectbreakdowncauselowvoltageand

highcurrent.

7.Aftertestover,anticlockwiserotatethevoltagebuttontobottom,press

poweroff,switchoffpowerandequipmentautomaticallydischarge,andmake

grounding.Putthekeyswitchtooffposition,takeoffthekey,takeadischarge

rodtodischargethetestedobject,andthentakeoffHVoutputcable.

10.HVpulsetest

Forprelocationandpreciselocation,HVpulsedischargestofaultpoint.

HDBM-30/4cablefaultlocationpower



1.Start,asto8.3,8.4,8.5.Takedischargerod,makethetestedobject

discharged.Connectagoodgroundingwiretotestedobject.Connectwellthe

HVoutputwire,groundingwire,anddischargerod.

Aftercheck,takeoffthegroundingwireattestedobject,andgotonextstep.

2.Raisefunctionbutton,rotatetoHVpulsegear

3.Choosesingleorperiodical.Forprelocation,singleischosen.Forfault

preciselocation,chooseperiodicalmode.



4.Presspoweron,powerongreenlampisoff,andHVredlampison,and

equipmentispowered.

5.Rotatetheregulationbuttonanti-clockwisetobottom,pressHVon,andHV

onlampisoff,andthenHVison.

6.Accordingtotestrequirement,setoutputvoltage.Ifchoosesingle,press