分享

【PSC典型复议案例】消防设备标志和位置指示要求的理解争议

 糖加不啡咖 2018-07-02

1

检查情况

A 2010 built bulk carrier was inspected. Out of 8 deficiencies recorded, the company of the vessel appealed for the deficiency below:

对一条 2010年建造的散货船进行了检查。在记录的 8个缺陷中,船公司针对下述缺陷提请复议:

07122 Fire control plan -THE LOCATION SYMBOL OF FIRE CONTROL PLAN NOT IN ACCORDANCE WITH MSC/CIRCULAR.451 (Reference: SOLAS ch. II-2)

07122 防火控制图——防火控制图的位置符号不符合 MSC/CIRCULAR.451规定(参考: SOLAS 第 II-2章)

2

船旗国意见

1.The said vessel was displaying the latest Fire control plan IMO symbol “The Dash type”(see above pictures) on cylindrical containers containing the Fire control Plan stowed next to the main deck Superstructure near Accommodation ladders (P & S) which is in accordance with Res. A 952(23) for ships built on or after 01/01/2004. 

该船采用了最新防火控制图的 IMO符号“破折线类型”(参见上图)进行标识显示,该符号标识设置在了装有防火控制图的圆柱形容器上方,其中,所述圆柱形容器装配于舷梯附近的主甲板上层建筑旁边,这种设置模式符合 A 952(23)决议针对 2004年 1月 1日或以后建造的船只的规定。

2.PSC quoted the Circular MSC.451 dated 24/09/1986 in their PSC Report to indicate vessel not displaying the IMO Symbol for Fire Plan as per MSC.451 circular (i.e. Sticker of “Burning ship”), which has been long back replaced by “Dash type” fire symbol.  

PSC在 PSC报告中援引了 1986年 9月 24日发布的 MSC.451通函内容,以表明船舶未依据 MSC.451通函(即“船只燃烧”的标志)规定显示防火控制图 IMO符号,其中,该符号早已使用“破折线类型”的消防标识。

3.It is understood that ships built before 01/01/2004would not be required to revise their Fire Control Plans, provided their shipboard symbols are in compliance with those symbols contained in Resolution A.654(16) and ships built after 01/01/2004 should use the updated symbols contained in Resolution A.952(23) in their Fire Control Plans.

据悉, 2004年 1月 1日之前建造的船舶不需要修改其防火控制图,只要船上使用的符号符合 A.654(16)决议中的符号要求,且 2004年 1月 1日以后建造的船舶应在其防火控制图中使用 A.952(23)规定的最新符号即可。

3

参考资料  

1.there are different understanding or interpretation on location symbol/sign for fire control plan between PSCO and the ship/company.

PSCO和船舶以及船公司之间针对防火控制图的位置符号或标志的理解或解释具有一定差异。

2.based on SOLAS CH Ⅱ-2 reg 15.2 it appear to be logical that resolution A.952(23) would be referred to for graphical symbols including fire plan location sign wile MSC/cir451 would be referred to for the duplicate set of fire control plan stored outside deckhouse except for the location.

根据 SOLAS第 II-2章第 15.2条款,包括防火控制图位置标志在内的图形符号应参照 A.952(23)决议要求,同时,除位置标志 /设计外,存放在甲板室外的一组备份防火控制图应参照 MSC/Circ.451规定。

4

问题探讨

Do you consider the deficiency justified?

你认为该缺陷是否合理?





    本站是提供个人知识管理的网络存储空间,所有内容均由用户发布,不代表本站观点。请注意甄别内容中的联系方式、诱导购买等信息,谨防诈骗。如发现有害或侵权内容,请点击一键举报。
    转藏 分享 献花(0

    0条评论

    发表

    请遵守用户 评论公约

    类似文章 更多