SHIP SECURITY ALERT SYSTEM (SSAS)
(For FELCOM12/15/16)Your Local Agent/Dealer Your Local Agent/Dealer
9-52 Ashihara-cho, 9-52 Ashihara-cho,
Nishinomi Nishinomiy ya 662-8580, JAPAN a 662-8580, JAPAN
Te Telle ep phone : hone : 0798-65-2111 0798-65-2111
Fa Fax x 0798-65-4200 0798-65-4200
::
F FIRST EDITION : IRST EDITION : MAY MAY 2004 2004
Printed in Japan Printed in Japan
A All r ll riig ghts reserved. hts reserved.
C C :: DEC DEC.. 01, 2004 01, 2004
Pub. No. Pub. No. OME-56351 OME-56351
00015035902 00015035902
00015035902 00015035902
( ( DAMI DAMI ) ) IC-307(SSAS) IC-307(SSAS)
0 0 0 1 5 0 3 5 9 0 2 0 0 0 1 5 0 3 5 9 0 2
OME OME56351 56351CC00 00
OME OME56351 56351CC00 00
O M E 5 6 3 5 1 C 0 0 O M E 5 6 3 5 1 C 0 0
TABLE OF CONTENTS
SYSTEM CONFIGURATION .........................................................................................2
1. OVERVIEW OF SSAS ..............................................................................................4
2. INSTALLATION.........................................................................................................6
2.1 Mounting......................................................................................................................... 6
2.1.1 Junction box (for FELCOM 16) ............................................................................... 6
2.1.2 I/F box IC-312 (for FELCOM 12)............................................................................. 7
2.1.3 SSAS alert unit ....................................................................................................... 8
2.2 Wiring............................................................................................................................ 10
2.2.1 Junction box (for FELCOM 16) ............................................................................. 10
2.2.2 I/F box IC-312 (for FELCOM 12)........................................................................... 11
2.2.3 SSAS alert unit ..................................................................................................... 12
2.3 Initial Settings................................................................................................................ 13
3. OPERATION............................................................................................................14
3.1 Operation Mode ............................................................................................................ 14
3.1.1 Changing the password ........................................................................................ 14
3.1.2 SSAS manager mode........................................................................................... 15
3.2 Setting SSAS Report Destination and Message Contents............................................. 16
3.3 Transmitting SSAS Report ............................................................................................ 19
3.4 Testing the Button .........................................................................................................21
3.5 SSAS Report Test ......................................................................................................... 27

OUTLINE DRAWINGS...............................................................................................D-1
INTERCONNECTION DIAGRAMS ...........................................................................S-1
1
SYSTEM CONFIGURATION
Regulations require at least two SSAS alert units.
FELCOM 15
ANTENNA
UNIT
IC-115
DGPS
EGC Printer
24 VDC
PP-50
100/115/220/230 VAC
TERMINAL UNIT
1φ, 50/60 Hz
IC-215
Personal
AC-DC Power Supply
Printer
Computer
PR-240-CE1
(PC/AT compatible)
12/24
GPS receiver
VDC
OP16-24
Shipboard LAN (Ethernet)
Printer
24 VDC
PP-510
Mini Keyboard
Distress Alert/
Received Call Unit
IC-305
Distress Message Controller
DMC-5
JUNCTION
Alarm Unit
BOX
OR
IC-306
IC-315
SSAS Alert Unit SSAS Alert Unit
IC-307
IC-307
: Standard Supply
Navigator
(Max. 3 units)
: Option
1 Any AC-DC power supply
: Local Supply
fulfilling requirements of
IEC 60945 may be used.

FELCOM 16
ANTENNA
UNIT
IC-116
AC-DC
100/115/220/230 VAC
PRINTER
Power Supply
1 φ, 50/60 Hz
COMMUNICATION UNIT IC-216
PR-240-CE
(with internal GPS receiver)
12-24 VDC
PERSONAL
FURUNO INMARSAT MINI-C MOBILE EARTH STATION
COMPUTER
O POWER I
(PC/AT compatible)
: Standard
JUNCTION BOX
SSAS ALERT UNIT SSAS ALERT UNIT
: Option
IC-315
IC-307 IC-307
: Local Supply
(Max. 3 units)
: SSAS only

2
POWER
LOGIN
TX
ERROR
FELCOM 12
Antenna Unit
IC-112
Navigator
100/110/200/220V
1φ, 50/60 Hz
Communication Distress Alert Unit
AC-DC
Unit
IC-302
Power Supply
IC-212
PR-300
INMARSAT-C MOBILE EARTH STATION
24 VDC
Received Call Unit
POWER
ON OFF
IC-303
Distress Alert Unit
Terminal Unit
IC-302
IB-581/IB-582
OR
24 VDC
Distress Message Controller
24 VDC
DMC-5
24 VDC
Priinter
POWER BRIGHT CONTRAST
PP-510
SSAS Alert Unit
Interface 24 VDC
Mini Keyboard
IC-312
PC
(PC/AT compatible)
SSAS Alert Unit
IC-307
OR
Terminal Unit
SSAS Alert Unit
IB-581/IB-582
IC-307
: Standard
(Max. 3 units)
: Option
: User Supply
: Choose one.
Terminal Unit
24 VDC
Required for cable extension (max.100 m)
IB-581

I/F Box
OP16-14
EGC Printer
24 VDC
PP-505


3
1. OVERVIEW OF SSAS
The IC-307 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES
FELCOM 15/FELCOM 12 or the Inmarsat Mini-C FELCOM 16 for the purpose of alerting
specified addresses (for example, your ship’s company) that your ship is under attack by
intruders. The SOLAS Resolution XI-2/6 requires vessels of 500 GT or more constructed
before 01 July 2004 to install an SSAS.

When your ship is under attack an SSAS report, which contains your ship’s name, MMSI
No., position, etc. is sent to up to five locations, specified by the ship’s captain or authorized
personnel. No audible or visible alarm is generated while the SSAS report is being
transmitted, to prevent discovery of the report by the intruders.

The SSAS is protected with a password to prevent unauthorized setting or testing of it by
other than the ship’s captain or authorized personnel.
Inmarsat System
Ship Name, MMSI No.,
Ship Position, etc.
Headquarters
Ship
Ship''s Company,
Management Company

4
SSAS operation flow
1. Open the cover of the button and then press the button.
(This is a latch-type button; hit and release to activate the button.)

2. If addresses have been preset, the SSAS report is sent to one
address 30 seconds after the button is activated.
(Max. 5 addresses)
(You may cancel transmission of the SSAS report by pressing the
button again within 30 seconds of the initial press.)

3. An LES sends acknowledgement to your ship.
4. Steps 2-3 and are repeated in case of multiple addressees.

5. Continuous transmission of the SSAS report begins.
(The interval at which to transmit the SSAS report to each address
can be specified. The SSAS report is continuously transmitted
while the button is ON, at the interval selected.)

6. To stop transmission, press the button again to deactivate it.
(This is only possible in the SSAS manager mode. See
paragraph 3.1.)

5
2. INSTALLATION
2.1 Mounting
2.1.1 Junction box (for FELCOM 16)
The junction box IC-315 is required when installing the SSAS on the FELCOM 16; it is
already installed on the FELCOM 15.

Separate the junction box from a magnetic compass by the distances shown below to
prevent deviation to a magnetic compass.

Standard compass: 1.0 m
Steering compass: 0.7 m

1. Remove four screws from the unit to separate the cover from the unit.
2. Fix the unit to the mounting location with four self-tapping screws (4x16, supplied).
3. Connect the cables appropriately referring to paragraph 2.2.1.
120 ±0.5
70 ±0.5

Junction box IC-315
The junction box is connected to the communication unit with a 2 meter cable, with D-sub
connector (at the communication unit). Therefore, locate the junction box within two meters
of the communication unit.
6
2.1.2 I/F box IC-312 (for FELCOM 12)
The I/F box is required to connect the SSAS alert unit to the FELCOM 12.

The I/F box is connected to the communication unit with a 5 m cable (17JE-573-10 harness).
Accordingly, locate the interface within 5 m of the communication unit.

Keep the following compass safe distances in mind when choosing the mounting location:
Standard compass: 0.65 m
Steering compass: 0.45 m

1. Unfasten four screws to remove the cover.
2. Use four self-tapping screws (3X10, supplied) to fix the unit to the mounting location.
3. If the cable is led in from the rear of the unit, change the clamp location as follows:
a) Unfasten two screws to remove the clamp.
b) Turn the clamp 90 degrees.
c) Fasten the clamp.
Unfasten two screws.
Fasten clamp with two screws.
Clamp
Turn

4. Pass the cable through the clamp and connect it to the terminal board, referring to the
interconnection diagram.

7
2.1.3 SSAS alert unit
Separate the junction box from the SSAS alert unit by the distances shown below to prevent
deviation to a magnetic compass.

Standard compass: 0.70 m
Steering compass: 0.45 m

Locate the SSAS alert unit where it cannot be found by intruders. The location should be
known only by ship’s captain and authorized personnel.

Bulkhead mounting
1. Remove four screws from the unit to separate the bottom chassis from the top cover.
2. Fix the unit to the mounting location with four self-tapping screws (supplied).
3. The cable can be lead in from the bottom or the rear panel. For rear panel entrance,
change the clamp orientation as follows:
a) Unfasten three screws to remove the cable clamp.
b) Turn the clamp 90 degrees.
c) Refasten the clamp with three screws unfastened at step a) to fix the clamp.
Unfasten three screws.
Clamp
Rotate
Fasten three screws.

4. Run the cable thru one of the cable entrances and connect it to terminal board.
8
5. Attach the switch cover as shown below. Note that the cover may be turned 180° to
change cover opening direction.
Press here and hold down for five seconds.
Switch cover


Flush mounting
The optional flush mount kit OP16-28 (Code No. 004-448-010) is required.
Name Type Code No. Qty Remarks
Fixture 16-018-7201-1100-317-9311
Pan head screw M3x6 000-800-362 4
Self-tapping screw 4x16 000-802-080 4
1. Cut out the mounting position referring to the outline drawings at the back of this
manual.
2. Fix the unit to the fixture with four pan head screws (supplied).
3. Fasten the fixture with the unit to the mounting location with four self-tapping screws
(supplied).
4. Attach switch cover as shown above.
9
2.2 Wiring
2.2.1 Junction box (for FELCOM 16)
Use the junction box IC-315 to connect the SSAS alert unit to the FELCOM 16. Unfasten
four screws to remove the cover to connect cables to terminal board. For detailed wiring
information see the interconnection diagram.

For connection, use the JIS cable TTYCS-4 (or equivalent, see next page for sectional view
of this cable) or the CO-SPEVV-SB-C 0.2x5P. When using the CO-SPEVV-SB-C 0.2x5P
cable, replace the cable clamp with the cable clamp 16-018-6008-1, supplied with the
junction box.
1 Vcc
GND
2
TD/RD-A
3
TD/RD-B
4
NC
5
Cover
TD-A(NAV)
6
1
TD-B(NAV)
7 2
RD-A(NAV)
8
RD-B(NAV)
9
GND
10
DMC OUT-H
11
DMC OUT-C
12
Cable clamp
DMC IN-H
13
(top)
3
Core 7 mm
14 DMC IN-C
DMC CTR
15
Terminal
board
Communication
Unit
Cable clamp
Cable clamp
Procedure
(bottom)
1. Insert driver from direction 1 .
2. Tilt slightly toward 2 .
3. Insert cable core to 3 .
Note 1: Do not insert the cable too
deeply, to prevent pinching the sheath.
Fold back braided shield onto
Note 2: Pull each cable slightly to con-
sheath and fix by cable clamp.
firm that they are in their holes securely.
16S0344
15mm 90mm 7mm

Junction box IC-315
10
IC-305/306
2.2.2 I/F box IC-312 (for FELCOM 12)
FELCOM 12 is connected to the SSAS Alert Unit via the I/F Box IC-312.

For detailed wiring refer to the interconnection diagram at the back of this manual.
Communication Unit
(rear view)
BUZZER DMC1 DMC2 ANT BREAKER 24VDC
NMEA
DTE 1 DTE 2 DATA
OR
24 VDC
MJ-A3SPF0016-035 (3.5 m)
17JE-573-10 Harness (5 m)
Twist shield.
CO-SPEVV-SB-C 0.2X5P
or TTYCS-4
16P0231
Cut and tape
unused wires
15 mm 40 mm
to prevent short.
123456
Clamp for cable
CO-SPEVV-SB-C 0.2X5P
Armor
Sheath
Clamp for cable
TTYCS-4 (or equivalent)
Shield
Conductor
2
S = 0.75 mm
φ = 1.11 mm
Sectional view of cable TTYCS-4
Cable from
SSAS Alert Unit

Wiring I/F box IC-312
11
2.2.3 SSAS alert unit
Three SSAS alert units can be connected. For wiring, see the illustrations below and the
interconnection diagram at the back of this manual. For the terminal unit (FELCOM 15) and
the communication unit (FELCOM 16/FELCOM 12), the wiring of the SSAS is monitored
and if in error “TROUBLE: SSAS UNIT connection abnormality.” is displayed. Further the
ERROR lamp (FELCOM 16) flashes.
Junction
Box
IC-307
IC-307 IC-307
(No.1) (No. 2) (No. 3)

Connect wiring to the terminal board 16P0229 inside the SSAS unit. To differentiate
between units in case of multiple unit installation, change jumper block settings as shown
below, in accordance with how many units are installed.
Jumper settings for two IC-307 Jumper settings for three IC-307
Unit Unit
No.1 unit No. 2 unit No.1 unit No. 2 unit No. 3 unit
Jumper : Default Jumper
setting JP1
JP1 No Ye s No No Ye s
JP2 Ye s No JP2 Ye s Ye s
No
No. 1 unit: Unit with two cables connnected to it. No. 1 and No. 2 units: Units with two cables connnected to them.
No. 2 unit: Unit with one cable connnected to it. No. 3 unit: Unit with one cable connnected to it.
Two IC-307: No. 2 Two IC-307: No. 1
Three IC-307: No. 3 Three IC-307: No. 1 and No. 2
16P0229 16P0229
JP1 JP2
JP1 JP2
123456 123456
IC-307 IC-307
Cable Fabrication
Twist shield.
Clamp for cable
CO-SPEVV-SB-C 0.2X5P
CO-SPEVV-SB-C
or TTYCS-4
0.2x5P
Cut and tape
unused wires
15 mm 40 mm 10 mm
to prevent short.
f = 16.3 mm
Clamp for cable
Armor
TTYCS-4
or equivalent Sheath
Shield
Conductor
2
S = 0.75 mm
φ = 1.11 mm
Sectional view of cable TTYCS-4

Wiring inside the SSAS alert unit
12
2.3 Initial Settings
Set up the SSAS as follows:

1. FELCOM 15/FELCOM 12: Press [F8], [F2] to show the System Setup menu.
FELCOM 16: Press [F8], [F1] to show the System Setup menu.
2. Press [ ↓] to choose Command Window and then press the [Enter] key.
Command Window Command Window
RFCONCPU RFCONCPU
[ Main Menu ] [ Main Menu ]
1. Remote Box Setup
1. Remote Box Setup
Enter JOB No. :
2. Internal GPS Setup
Enter JOB No. :
FELCOM 12
FELCOM 15/FELCOM 16

3. Type “furunoservice” (without quotation marks) in the Enter JOB No. field and then press
the [Enter] key. The prompt PASSWORD appears.
4. Enter password (see FURUNO Information for SSAS) then press the [Enter] key. Then,
the item Main Menu is displayed in reverse video.
5. Press [1], [Enter], [1], [Enter]. One of the following windows appears.
[ DMC ]
[ SSAS ]
1. SSAS
1. ON
2. DMC
2. OFF E: Exit
3. OFF E: Exit Enter No.:
Enter No.:
FELCOM 15 FELCOM 16
[ SSAS I/F (IC-312) ]
1. DTE2 Port
2. DATA Port
3. OFF E: Exit
Enter No.:
FELCOM 12

6. FELCOM 15/FELCOM 16: Press [1], [Enter]. This enables the SSAS functions.
FELCOM 12: Choose the port where the SSAS unit is connected and then press the
[Enter] key.
7. Press the [Esc] key several times to close the menu.

Note: Test the SSAS button and SSAS report for proper operation, referring to paragraphs
3.4 and 3.5, respectively.
13
3. OPERATION
3.1 Operation Mode
There are two menu operating modes:

Normal mode: Menus other than SSAS-related menus are displayed.
SSAS manager mode: The mode is activated by the password entered by the ship’s
captain or authorized personnel. The indication “SSAS Manager
Mode” is shown at the top of the screen when this mode is
activated, and it is flashing on the FELCOM 15/FELCOM 16. All
SSAS-related menus are available. Transmission of the SSAS
report may be cancelled in this mode. The equipment starts up in
the normal mode, regardless of the mode in use when the power is
turned off.

3.1.1 Changing the password
The default password is “ship security alert”. Ship’s captain or authorized personnel may
change the password as follows:

1. FELCOM 15/FELCOM 12: Press [F8], [F2] to show the System Setup menu.
FELCOM 16: Press [F8], [F1] to show the System Setup menu.
2. Press [ ↓] to choose Command Window and then press the [Enter] key.
Command Window Command Window
RFCONCPU
RFCONCPU
[ Main Menu ]
[ Main Menu ]
1. Remote Box Setup 1. Remote Box Setup
2. Internal GPS Setup Enter JOB No. :
Enter JOB No. :
FELCOM 15/FELCOM 16 FELCOM 12

3. On the Enter JOB No. field, type “ssas password” (without quotation marks) and then
press the [Enter] key. The prompt OLD PASSWORD appears.
4. Type your current password and then press the [Enter] key. The prompt NEW
PASSWORD appears.
5. Enter new password, using at least six characters, and then press the [Enter] key. The
prompt RETYPE NEW PASSWORD appears.
Note: If less than six characters are entered for the password, the message “Please
use a longer password.” appears. Enter a longer password.
6. Enter new password again and then press the [Enter] key. The message “Password
changed” appears.
7. Press the [Esc] key several times to close the menu.

Note: The SSAS manager mode cannot be unlocked without the proper password.
14
3.1.2 SSAS manager mode
All SSAS-related settings are set in the SSAS manager mode. Do the following to access
this mode.

1. FELCOM 15/FELCOM 12: Press [F8], [F2] to show the System Setup menu.
FELCOM 16: Press [F8], [F1] to show the System Setup menu.
2. Press [ ↓] to choose Command Window and then press the [Enter] key.
Command Window Command Window
RFCONCPU
RFCONCPU
[ Main Menu ] [ Main Menu ]
1. Remote Box Setup 1. Remote Box Setup
2. Internal GPS Setup Enter JOB No. :
Enter JOB No. :
FELCOM 15/FELCOM 16 FELCOM 12

3. On the Enter JOB No. field, type “ssas manager” (without the quotation marks) and then
press the [Enter] key.
4. Type password and then press the [Enter] key to go into the “SSAS Manager Mode”.
The indication “SSAS Manager Mode” is shown at the top of the screen when this mode
is activated, and it is flashing on the FELCOM 15/FELCOM 16.
CAUTION
04-04-20 05:37 (UTC)
SSAS Manager Mode enabled.


5. Press the [Esc] key several times to close the menu. This enables the SSAS manager
mode, which allows you to execute the procedure in paragraph 3.2.

Note: Turn the power off and on again whenever changing SSAS-related settings.
15
3.2 Setting SSAS Report Destination and
Message Contents
When the SSAS is activated, the SSAS report is sent according to the addresses (max. 5)
and message content set with SSAS Report 1 – SSAS Report 5 on the SSAS Report menu.
Note 1: The destination and message content of an SSAS report varies according to
Administration. Therefore, set them as requested by ship’s authorities. For
information other than ship’s name, MMSI no. and IMN no., set it manually with
“Other Inf.”
Note 2: The equipment must be in the SSAS manager mode to execute this procedure.
See paragraph 3.1.2.
1. Press the [F5] to open the Reports menu.
Reports
1. Data Report
2. Message Report
3. Data Network ID
4. SSAS Report

2. Press the [4] key to shown the SSAS Report menu.
SSAS Report
1. SSAS Report 1
2. SSAS Report 2
3. SSAS Report 3
4. SSAS Report 4
5. SSAS Report 5
6. Message Contents

3. Press [1], [2], [3], [4] or [5] key as appropriate. (When the button is tested, a test report is
sent to the address specified for the youngest SSAS report number. Therefore, set the
address which is to receive the test report set for the youngest SSAS report number.)
SSAS Report
Status ON
Station Name
Destination Type TELEX
Prefix Code
Country/Ocean Code
Station ID
Modem Type
Address
Subject
LES ID
02:00 (hh: mm)
Report Interval

4. If you are sending an SSAS report to a registered station, press the [ ↓] key to choose
Station Name and then press the [Enter] key.
Note: To send an SSAS report by telex, fax or e-mail or an SMS report
(FELCOM15/FELCOM16) to a station not registered, see “Transmitting a
message to a station not registered on station list” on page 4-8 in the Operator’s
Manual, issued separately.
16
5. Press the [ ↑] or [ ↓] key to choose appropriate station and then press the [Enter] key.
You may sort the list by group name, station name or communication type as follows:
Group name: Each press of [Ctrl] + [G] sorts the list by group name, ascending
or descending order.
Station name: Each press of [Ctrl] + [N] sorts the list by station name, in
ascending or descending order.
Comm. type: Each press of [Ctrl] + [T] sorts the list by communication type, in
ascending or descending order.
6. Press the [ ↓] key to choose LES ID and then press the [Enter] key.
7. Press the [ ↑] or [ ↓] key to choose LES and then press the [Enter] key.
Note: Change the LES whenever sea area has changed. However, the equipment
automatically searches for an LES with which you can communicate and the
SSAS report is transmitted to that LES.
8. Press the [ ↓] key to choose Report Interval and then press the [Enter] key.
9. Enter time interval (00:10-99:59) to transmit the SSAS report and then press the [Enter]
key.
After the SSAS report is transmitted and the button remains “ON” ( ), the SSAS report
is transmitted at the interval set here.
10. Press the [Esc] key to open the Update window on the FELCOM 15/FELCOM 16 or the
Entry window on the FELCOM 12.
SSAS Report
ON
Status
Station Name
TELEX
Destination Type
Prefix Code
Country/Ocean Code
Station ID
Modem Type
Address
Update
Subject
LES ID
Yes No
Report Interval 02:00 (hh: mm)

Update window (FELCOM 15/FELCOM 16)
11. Yes is selected; press the [Enter] key to close the SSAS report window.
12. Press the [6] key to display the SSAS Message Contents menu.
SSAS Message Contents
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Vessel Name :
_ _ _ _ _ _ _ _ _
MMSI :
IMN : _ _ _ _ _ _ _ _ _
Other Inf. : _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
34: 44. 46N
LAT:
135: 21. 26E
LON:
02/04/2004 04:31:48 (UTC)
Time:
071 deg
COURSE:
00 kt
SPEED:
02/04/2004 04:31:48 (UTC)
Time:

13. Press the [Enter] key to open the Vessel Name window.
17
14. Enter vessel’s name and then press the [Enter] key.
15. Press the [ ↓] key to choose MMSI and then press the [Enter] key.
16. Enter MMSI number and then press the [Enter] key.
17. Press the [ ↓] key to choose IMN and then press the [Enter] key.
18. Enter IMN and then press the [Enter] key.
19. Press the [ ↓] key to choose Other Inf. and then press the [Enter] key
20. Enter appropriate message (three lines) and then press the [Enter] key.
Note: To shift between lines, use the [ ↑] or [ ↓] key.
21. Press the [Esc] key to open the Update window on the FELCOM 15/FELCOM 16 or the
Entry window on the FELCOM 12.
22. Yes is selected; press the [Enter] key to close the SSAS Message Contents menu.
23. Press the [Esc] key twice to return to the standby display.

Note 1: To delete entered subscriber’s data, choose “Remove” from “Status.”
Note 2: SSAS report settings may be saved to a floppy disk for backup, on the FELCOM
15/ FELCOM 16.
FELCOM 15: [F8], [9], [6] to show the Save/Load window.
FELCOM 16: [F8], [8], [6] to show the Save/Load window.
Load from FD
Save to FD
1. ALL 1. ALL
2. Station List
2. Station List
: Availlable only in SSAS manager mode
3. LES List
3. LES List
("5.SSAS Report" is added in the SSAS
4. E-Mail/SMS List 4. E-Mail/SMS List
manager mode and item numbers are shifted.)
5. SSAS Report 5. SSAS Report
6. Other 6. Other

Note 3: To confirm the settings, follow paragraph 3.5.
18
3.3 Transmitting SSAS Report
In the normal mode, the SSAS report is sent 30 seconds after the button on the SSAS is
pressed. The SSAS repeatedly transmits the report even if the button is pushed off ( ).
Repeated transmission can only be stopped from the SSAS manager mode.

1. Open the cover of the SSAS alert button.
Cover

2. Push the button. The button is a latch-type button; hit and release the button to activate
( ) the SSAS unit.
3. The SSAS report is transmitted 30 seconds after the button is pushed in ( ). Below are
the contents of the SSAS report.
- - - SSAS ALERT MESSAGE - - -
Vessel Name: Queen Elizabeth 2 Ship''s Name
MMSI: 111660000 MMSI No.
IMN: 443100000
IMN No.
Help me!
Desired message
LAT: 34:44.46N
Own ship postion in latitude
LON: 135:21.26E
Own ship position in longitude
Time: 02/04/2004 04:31:48 (UTC) Time of position data
COURSE: 071 deg Course
SPEED: 00 kt Speed
Time: 02/04/2004 04:31:48 (UTC)
Time of course and speed data

Note: If you accidentally push the button in, push it again within 30 seconds to cancel
the report. The button pops out ( ) and the report is not transmitted. When this
is done, the message “INF: SSAS UNIT activation has been canceled.” appears
on the display. Additionally, for the FELCOM 16, the POWER lamp on the
communication unit flashes 30 seconds.
4. An LES sends acknowledgement to your ship.
5. For multiple destinations, steps 3 and 4 are repeated.
6. The SSAS report is transmitted repeatedly while the button remains pushed in ( ).
7. To stop transmission, push the button again to pop it out ( ). (SSAS manager mode
only.)

19

Note 1: You may cancel repeated transmission from either operating mode by pushing the
button OFF →ON →OFF →ON →OFF. You must allow no more than three seconds
to elapse before pushing the button again. If more than three seconds elapses,
repeat the procedure. When transmission is stopped, the message “INF: SSAS
UNIT activation has been cancelled.” appears and, on the FELCOM 16 only, the
POWER lamp on the communication unit flashes approx. 30 seconds.
Note 2: If transmission is not canceled with the button and the power is turned off, the
equipment resumes repeated transmission when powered again.
20
3.4 Testing the Button
The SSAS buttons can be tested as below.

Note 1: An actual SSAS report cannot be transmitted during the testing.
Note 2: The equipment must be in the SSAS manager mode to conduct the test.

FELCOM 15
1. Press the [F7] key to display the Options menu.
2. Press the [7] key ([6] key when the FELCOM functions as an EGC receiver) to display
the Test menu.
Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. Distress/SSAS Button Test

3. Press the [4] key.
Options
Test
1. Login
Distress/SSAS Button Test
2. Logout
1. PV Test
3. Abort
2. PV Test Result
Start
4. Select NCS
3. Self Test
5. Ocean Region
4. Distress Alarm Button Test
Yes No
6. Test

4. Press the [Enter] key to start the test.
Options
Test
1. Login
Distress/SSAS Button Test
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
3. Self Test Distress/SSAS buttons are under test mode.
CAUTION
5. Ocean Region
4. Distress Alarm Button Test Press any key to escape.
INF: Distress/SSAS Buttons entered into TEST MODE.
6. Test


The display shows the message (in red) “Distress/SSAS buttons are under test. Cancel
the test mode if a real distress/SSAS needs to sent.” appears.
5. Open the button cover on the No.1 SSAS.
6. Push the button in ( ). The CAUTION window displays the message “SSAS UNIT
works correctly.” appears if the unit is functioning properly.
Note: 30 seconds after step 6, the SSAS test report is automatically sent. If you do not
need to send the SSAS report, go to step 8 within 30 seconds.
7. The SSAS test report is automatically sent once to the address specified for the
youngest SSAS report number (1-5).
8. Turn the button of the No. 1 SSAS off ( ).
Note: To test the No. 2 and No. 3 SSAS repeat steps 6-8.
21
9. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is
stopped and the message shown below appears to notify you that normal operation has
been restored.
CAUTION
INF: Distress/SSAS Buttons returned to NORMAL OPERATION.


Further, because the button remains pushed in ( ), the message “Please return the
SSAS button into OFF-STATE.” appears.
10. Push the button again to pop it out ( ).
11. Close the button cover.
12. Press the [Esc] key three times to return to the standby display.

Note: If the button is left pushed in ( ) when the terminal unit is turned on, the equipment
displays “Please return the SSAS button into OFF-STATE.” Push the button again to
turn off ( ) the button.

22
FELCOM 16 (no PC)
Turn off communication unit.
Turn on button of No. 1 SSAS.
Turn on communication unit.
30 s
POWER, LOGIN and TX lamps flash
together.
Send SSAS No (within 30 s)
test report?
Yes (after 30 s)
SSAS report is sent to sub- scriber
specified in youngest SSAS report
number. Lamps flash during TX.
Test TX
No
Test ERROR lamp flashes rapidly.
successful?
Ye s
POWER, LOGIN and TX lamps flash
together. ERROR lamp also flashes.
Turn off button of No. 1 SSAS.
The POWER, LOGIN, TX and POWER
lamps light in that order.
Turn on button of No.2 SSAS.
POWER, LOGIN and TX lamps flash
together.
Test TX
Turn off button of No.2 SSAS.
Note: If a 3rd SSAS unit is installed
test it by procedure used to test
See note.
No.2 unit.
Turn communication unit off and
on again.

23
FELCOM 16 (by PC)
1. Press the [F7] key to display the Options menu.
2. Press the [7] key ([6] key when the FELCOM functions as an EGC receiver) to display
the Test menu.
Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. SSAS Button Test

3. Press the [4] key.
Options
Test
1. Login
SSAS Button Test
2. Logout
1. PV Test
3. Abort
2. PV Test Result
Start
4. Select NCS 3. Self Test
5. Ocean Region
4. Distress Alarm Button Test
Yes No
6. Test

4. Press the [Enter] key to start the test.
Options
Test
1. Login
Distress/SSAS Button Test
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
3. Self Test Distress/SSAS buttons are under test mode.
CAUTION
5. Ocean Region
4. Distress Alarm Button Test Press any key to escape.
INF: Distress/SSAS Buttons entered into TEST MODE.
6. Test


Test mode
The display shows the message (in red) “SSAS buttons are under test. Cancel the test
mode if a real SSAS alert needs to sent.” appears.
5. Open the button cover on the No. 1 SSAS.
6. Push the button in (ON). The CAUTION window displays the message “SSAS UNIT
works correctly.” appears if the unit is functioning properly.
Note: 30 seconds after step 6, the SSAS test report is automatically sent. If you do not
need to send the test report, go to step 8 within 30 seconds.
7. The SSAS test report is automatically sent once to the address specified for the
youngest SSAS report number (1-5).
8. Turn the button of the No. 1 SSAS off ( ).
Note: To test the No. 2 and No. 3 SSAS repeat steps 6-8.
9. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is
stopped and the message shown below appears to notify you that normal operation has
been restored.
CAUTION
INF: SSAS Buttons returned to NORMAL OPERATION.


24

Further, because the button remains pushed in ( ), the message “Please return the
SSAS button into OFF-STATE.” appears.
10. Push the button again to pop it out ( ).
11. Close the button cover.
12. Press the [Esc] key three times to return to the standby display.

Note: If the button is left pushed in ( ) when the communication unit is turned on, the
equipment will go into the test mode if the SSAS is not transmitting repeatedly. To
return to the standby display, push the button again to pop it out ( ) and then turn
the communication unit off and on again.

FELCOM 12
1. Press the [F7] key to open the Options menu.
2. Press the [6] key if the FELCOM 12 operates as an Inmarsat C MES or the [5] key if it
operates as an EGC receiver.
Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. SSAS Button Test

Test menu
3. Press the [4] key.
Options
Test
1. Login
Distress/SSAS Button Test
2. Logout
1. PV Test
3. Abort
2. PV Test Result
Start
4. Select NCS
3. Self Test
5. Ocean Region
4. Distress Alarm Button Test
Yes No
6. Test

Start window
4. Press the [Enter] key to start the test mode.
Options
Test
1. Login
Distress/SSAS Button Test
2. Logout
1. PV Test
3. Abort
2. PV Test Result
4. Select NCS
3. Self Test Distress/SSAS alert button test mode.
CAUTION
5. Ocean Region
4. Distress Alarm Button Test Press any key to escape.
INF: DMC/SSAS switch TEST started.
6. Test

Display during testing
5. Open the cover of the No. 1 SSAS unit.
6. Press the button of the No. 1 SSAS unit to turn on ( ) the unit.
The CAUTION window displays the message “SSAS UNIT works correctly.” if the unit is
functioning properly.
25

Note: 30 seconds after step 6, the SSAS test report is automatically sent. If you do not
need to send the test report, go to step 8 within 30 seconds.
7. 30 seconds after the completion of step 6, the SSAS test report is automatically sent
once to the address specified for the youngest SSAS report number (1-5).
8. Turn the button of the No. 1 SSAS off ( ).
Note: To test the No. 2 and No. 3 SSAS repeat steps 6-8.
9. After the test is completed, press the [Esc] key on the keyboard twice to return to the
standby mode. The following message appears.
CAUTION
INF: DMC/SSAS switch TEST terminated.

Display at completion of test
Further, with the button left in the “ON” state ( ) the message “[Please return the SSAS
button into OFF-STATE.” appears.
10. Press the button again to turn it off ( ).
11. Close the button cover.
12. Press the [Esc] key three times to return to the standby display.
Note: If you turn off the communication unit with the button of an SSAS unit turned on ( )
the message “Please return the SSAS button into OFF-STATE.” appears. Press the
button to turn it off ( ).
26
3.5 SSAS Report Test
You can test for successful transmission of the SSAS report to the address you specify,
without using the button. The test report message states “!!! Test Call !!!” to alert the
receiver of the message that it is a test call.

Note: This function is only available in the SSAS manager mode. Switch to this mode (see
paragraph 3.1.2) and then follow this procedure.

1. Press the [F5] key to open the Reports menu.
2. Press the [4] key to choose the SSAS Report menu.
3. Press the [1], [2], [3], [4] or [5] key as appropriate, and the SSAS report setting menu
appears.
4. Set destination where to transmit the test.
5. Press the [ ↑] key to choose Status and then press the [Enter] key.
6. Press the [ ↓] key to choose TEST and then press the [Enter] key.
7. Press the [Esc] key to open the Update window on the FELCOM 15/FELCOM 16 or the
Entry window on the FELCOM 12.
8. Yes is selected; press the [Enter] key. The test report is transmitted. After it is
transmitted, “Status” is automatically set to ON.
9. Press the [Esc] key twice to return to the standby display.




271 2 3 4 5 6
アンテナ ユニット
アラ ーム ユニ ット IC-306
ANTENNA UNIT
ALARM U NIT
タ ーミナル ユニット
IC-115
16P0213B
ケー ブル:コネクタ、選択
TER MINAL U NIT
GND
1 VCC
CABLE : CONNECTOR, SELECT ED
IC- 215
P
RW-4747
2
DGPS 2 GND
BNC PLAG
0.3m
12D-S FA-CV,100m,φ15.6: N-P-120DSFA CO-AX (50Ω) DG PSデコーダー
TPA5FB 0.3NJ5
3
TD/RD-A
8D-FB -CV,50m,φ11.0: N-P -8DFB P
FBA-5D FB,0.3m DG PS DECODER
4 TD/RD-B
5 FG
A
ANT
TP 5FBAW-5DFBB,30m,φ 7.6
遭難警 報器 IC-305
接続箱
DISTRES S ALERT/
JUNCTIO N BOX
RECEIVE D CALL UNIT
IC-315
2B02 16P020 8A
JUNCTIO N D-sub15P
2
16P0213A
16S0344, 2m,φ9.2
TTYC S-4,φ16.3
1 チャ BRN 1 1 VCC
Vcc(ALM)
P
2
GND 2 ミドリ GRN 2 GND
K EYBOARD
キーボー ド
3 アカ RED 3 3 TD/RD-A
TD/RD-A
P
KEYBOARD
1 4
KDAT TD/RD-B 4 ハイ GRY 4 TD/RD-B
BTC-5100 C PS/2
2 5 5 5 FG
NC NC
3
GND TD-A 6 ダイ ORG 6 航法装置
NAV EQUIPM ENT
4 7 アオ BLU 7
+5V TD-B
保安警報 発呼器 保安警 報発呼器 保安警 報発呼器
CO-0.2x2P
5
KCLK RD-A 8 キ YEL 8 TX D-H
SSAS ALER T UNIT SSAS ALE RT UNIT SSAS AL ERT UNIT
6 9 クロ BLK 9
NC RD-B TX D-C IC-307 (No.1) IC-307 (No.2) IC-30 7 (No.3)
GND 10 モモ PNK 10 TB 3 7 TB 3 7 TB 3 7
11 ? ?/??1 BLU/RED1 11 1 1 1
DMC_OUT-H D MC_OUT-H SSAS _OUT-H SSA S_OUT-H SS AS_OUT-H
2 2 2
DMC_OUT-C 12 シロ WHT 12 D MC_OUT-C NC NC NC
船内LAN ( HUB)
P
LAN
5 RJ-45
13 ? ??/??1 ORG/WHT1 13 3 3 3
DMC_CHECK D MC_IN-H SSAS _CHECK SSA S_CHECK SS AS_CHECK
P
パソコン など Ethernet CABLE
1 4 4 4
E_TD_P DMC_IN-C 14 ? ???/??1 GRN/WHT1 14 D MC_IN-C SSAS _IN-C SSA S_IN-C SS AS_IN-C
B P
PC: CROSS CABLE
2 15 ? ??? PPL 15 5 5 5
E_TD-N DMC_CTRL D MC_CTR SSAS _CTRL SSA S_CTRL SS AS_CTRL
HUB: STRAIGHT C ABLE
L AN(HUB) OR PC, ETC.
3
E_RD_P 6 GND 6 GND 6 GN D
4
4
NC
P
5 2
NC
TT YCS-4,φ16.3 OR CO -0.2x5P
6
E_RD_N
7
NC 合計 :最 大200m
8 TOTAL:MA X.200m
NC
遭難警 報装置 DMC- 5
DISTRES S MESSAGE
CONTROL LER
2
17JE-23250
1 TB5
TTYCS -4,φ16.3
-02(D8C) 1
プリン タ 57-3036 PRINTER
1 DIST_IN-H
24V DC
P
VCTF-0.75 x3C
PRINTER
J1 1 1 2 DIST_IN-C
RH12BPG-3 S
5m,φ6.9
PP-510
アカ RED 1 3 DIST_OUT-H
24 VDC +24V
P
(16S0084)
クロ BLK 2
0V 4 DIST_OUT-C
3
シロ WHT 3 36 25 5 DIST_CTR
GND
6 GND
4 4
DT E
D-sub9P 3 D-sub9P
パソコ ン
2B03 16P020 9
17JE-573-10,5m, φ8
1 1 NC PC 5
C
CO-0.2x5P,15m M AX.
2 2
TXD RXD
FUSE
RXD 3 3 TXD
15A(12V)
MJ-A3SPFD 12-24VDC
4 4
DTR
7A(24V)
MJ-A3SPF00 18,5m,φ11
12-24 VDC 1
DC(+) GND 5 5 S.GND
シロ WHT
2 6 6
クロ BLK DC(-) DSR
3
GND 7 7 RTS
8 8
CTS
2B10 16P021 4
100-115/
2
9 9 NC
3
220-230 VAC
DPYC-2.5 CO-0.2x2P
+
24VDC
1φ,50/60Hz
4 4
φ12.8 AC_IN 15m MAX.
OUTPUT - FM14-7P E GCプリ ンタ
3
2
1
RXD E GC PRIN TER
PR-240- CE
DPYC-4
24 VDC
+ 24VDC 2 TXD P P-505
AC/DC電 源????
φ13.9 08S0157 ,3m
- 3 (+) 1
INPUT 0V 3 24VDC
AC/DC POWER
(-) 2
SUPPLY UNIT
7
NC
GN D
PE,IV-1.5SQ.
08 S0087
保護アース GND 銅板 3
FM14-5P FM14 -7P FM14-7P
W=30 COPP ER STRAP
注記 CO-0. 2x5P
1 RXD 1 1 RXD-H E GCプリ ンタ
05-003-0031,1 .2m
*1)工 場にて取付済み。 MAX.1 00m
2 2 2
TXD TXD-H E GC PRIN TER
P
*2)造 船所手配。
3 NC 3 3 FG P P-505 3 6
D P
*3)オ プション。
4 4 4
NC TXD-C
*4)コ ネクタクランプでア ースに落とす。 08S0157 ,3m
5 0V 5 5 RXD-C (+) 1 24VDC
*5)ユ ーザー手配。
6 6 (-) 2
+9V
I/F BO X
*6)TB 基板(16P0116)が 必要。
7 7 NC
OP16-1 4 3
*7)2 台または3台接続可能 。 GN D
08 S0087
終 端のIC-307はジャン パー設定の変更が必 要。
NOT E
DR AWN TITLE
1. FITT ED AT FACTORY.
FELCOM 15
Apr. 1 5 ''04 K. MIY AZA WA
2. SHIP YARD SUPPLY.
C HECKED
名称
3. OPTI ON.
インマルサットC船舶地球局
TAK AHA SHI .T
4. GROU ND THRU CONNECTOR CLAMP.
A PPROVED
5. USER SUPPLY.
相互結線図
6. TB B OARD (16P0116) REQ UIRED. CO-0.2x2P: CO-SPEV V-SB-C 0.2x5P,φ10 .5
S CALE MAS S
NAME
7. 2 OR 3 SETS CAN BE CON NECTED. CO-0.2x5P: CO-SPEV V-SB-C 0.2x5P,φ13 .5
IN MA RS AT- C ME S
kg
CHAN GE JUMPER SETTING IN LAST IC-307.
D WG No.
IN TE RC ON NE CT IO N D IA GR AM
C5635-C01- E
FURUNO ELECTRIC CO., LTD.
16S0184,3m, φ8
TNCP -NJ







1 2 3 4 5 6
アンテナユニット
インターフ ェイス 3
通信 制御ユ ニット
ANTENNA UNIT
I/F UNIT
1 7
PC/D ATA
COMM UNICATI ON UNIT
IC-112 ケーブル:コネ クタ(選択) RS-232C RS-422
KS- 10PT
17 JE-23090-02(D8C) 17J E-23250-02(D8C)
CABLE: CONNECT OR (SELECTED)
IC -212 J5 J3
R W-4747 17JE-573- 10,5m,φ8
12D-SFA-CV,100 m: N-P-120DSFA ANT 1 1
FG DATA OU T(+)
0 .37m
8D-FB-CV,50m: N-P-5DFB
2 2
J1 TXD RD DATA OU T(-)
N- H1054,0.3m 5D-FB-CV,30m: N-P-5DFB-1
3 3
RXD SD CONT OU T(+)
2
4 4
CS CONT OU T(-)
TTYC-1
RS-422 デ ータ出力装置
5 7
GND SG DATA I N(+)
A
RS-422 DAT A
6 6
ER DATA I N(-)
NMEA 7 5
RS CONT I N(+)
TTY CS-4(2) OR SRCN-6 A16-10P
8 8
航法 装置 J6 CONT I N(-)
CO- 0.2x2P
2
1 9 20
NAV EQUIPMENT TXD-H FG
P DPYC-1.5
100VAC,1φ,50/60H z
2 25
(NMEA0183) TXD-C SG
4
3
RXD-H 4
P
4
RXD-C
1 1
17JE -23090-02(D8C)
17JE- 13090-02(D8C) 保安警 報発 呼器 イン ター フェ イス
4
10 PC/DATA
J1
保安警報発呼 器 保安警報発呼 器 保安警報発 呼器
SSAS ALE RT UNIT I/F
17JE-573-1 0,5m,φ8
1
OR
IC-312 SSAS ALERT UNI T SSAS ALERT UN IT SSAS ALERT U NIT
3
2
TXD IC-307 (No.1 ) IC-307 (No. 2) IC-307 (No .3)
DTE-2
着信指示器 IC-303
RCV BZ 3
RXD TB TB 3 6 TB 3 6 TB 3 6
RECEIVED CALL UNIT
2
SRCN- 6A16-7P
4 1 1 1 1
J7 S SAS_OUT-H SSAS_OUT- H SSAS_OUT -H SSAS_OU T-H
TTYCS-4
16P0150
1 1 5 2 2 2
TB RBOUT-H GND NC 2 NC NC NC
P
P
2 2 6 3 3 3 3
RBOUT-C S SAS_CHECK SSAS_CHEC K SSAS_CHE CK SSAS_CH ECK
P
3 3 7 4 4 4
RBIN-H SSAS_IN-C 4 SSAS_IN-C SSAS_IN- C SSAS_IN -C
P
4 4 8 5 5 5 5
RBIN-C SSAS_CTRL SSAS_CTRL SSAS_CTR L SSAS_CT RL
5 5 9 6 6 6
RBCTR GND 6 GND GND GND
6 6
SHIELD
4 7 2
FU SE
B
TTYCS-4, φ16.3 OR CO-0.2x5 P
MJ-A3SP FD 24VDC
0. 5A
MJ-A3 SPF0016
合計 :最大200m
24VDC シロ WHT 1 +24V
遭難警報発呼器 IC-302 3.5m, φ11
DMC1 クロ BLK 2 TOTAL:MAX.200m
0V
DISTRESS ALERT UNI T
2
SRCN- 6A16-7P
3
J8 GND
TTYCS-4
16P0150
第2端末装置 用
1 1
TB DMCOUT-H
P
FOR SECOND DT E
2
2 DMCOUT-C
1 1
3 3 DTE-2
DMCIN-H
1
P
17 JE-23090-02(D8C) 17J E-13090-02(D8C)
ターミ ナル
4
4 DMCIN-C COM1 17JE-232 50-02(D8C)
J4 1
17JE-573-10,5m,φ 8
ユニッ ト
5 5 1 1
DMCCTR DCD 57-30 36
16S0 184,3m,φ8 プリンタ
TERMINA L UNIT
6
SHIELD 6 TXD 2 2 RXD
PRINTER
IB-581/ 582
4
7 3 3
RXD TXD
3
4 4 DTR
5 5
GND GND 1
DMC2 FM14-2P
6 6 DSR
遭難 警報発呼器 IC-302 2 VCTF-0.75x2 C,3m,φ7
SRCN- 6A16-7P
24VDC
7 7
J9 RTS
DIST RESS ALART UNIT TTYCS-4
1
DMCOUT-H 8 8 CTS
P
同上
2 9 9
DMCOUT-C R1
SAME AVOBE
FM 14-7P
3
DMCIN-H
4 4 FM1 4-5P I /F BOX
P
GND CO-0.2x5 P,MAX.100m
4
DMCIN-C
3
08S0087,2 m O P16-14
2
5 E GCプリン タ
DMCCTR F M14-7P
C
CO-0.2 x2P,MAX.15m DPYC-1.5
E GC PRINT ER 24V DC
6
3
4 7 P P-505
メイン端末装 置用
ター ミナルユ ニット
FOR MAIN DTE
1 1 TE RMINAL UNIT I B- 581 /5 82
DTE-1
17 JE-23090-02(D8C) 17JE-1 3090-02(D8C)
キー ボード
COM1 KEYBOARD
J3
17JE-573-10,5m,φ 8
KEYB OARD
1 1 1
DCD NC
BTC- 5100C PS /2
TXD 2 2 RXD DATA 2
1
3 3 3
RXD TXD VCC
HS16P-4 24VDC
J2
4 4 DTR GND 4
1 5 5 5
+24V GND GND NC
シロ WHT
2
+24V 6 6 DSR CLOCK 6
シロ WHT
3 7 7
0V RTS
クロ BLK
4
1
4
0V 8 8 CTS 1
クロ BLK
プリンタ
PRINTER
17 JE-23250-02(D8C)
9 9 57-303 6
R1
CN3 PRINTER
16S 0184,3m,φ8
2
AC /DC電源 ????
100/ 110/ 1 1 3
PP-510
4 4
DPYC-1.5
200/220 VAC
A C/DC POW ER
24VDC
1
I NPUT
1φ,50/ 60Hz
S UPPLY UN IT
J1
FM1 4-2P
2
P R-300 3 5 1 25 36
シロ WHT (+)
DPY C-4 GND 銅板
24 VDC 2
+ 2 4VDC 24VDC + (-)
クロ BLK
W=30 COPPER STRAP 4 4
D
- -
I NPUT OUTPUT
05-0 03-0031,1.2m
GND
08S0087, 2m
GND 2
IV-8SQ.
VCTF-0.75x 3C,5m,φ7
2 4 VDC
16S0084
注記 NOTE
DRAWN TITLE
*1)工場にて取 付済み。 1. FITTED AT FACTORY.
FELCOM 12
Jun. 3 ''04 K .MI YAZ AWA
*2)造船所手配 。 2. SHIPYARD S UPPLY.
CHECKED 名称
*3)オプション 。 3. OPTION.
インマルサットC船舶地球局
TAK AHA SHI .T
*4)コネクタク ランプでアースに落 とす。 4. GROUND THR U CONNECTOR CLAMP.
APPROVED
*5)船内電源に 応じてタップを替え る。 5. CHANGE TAP CONNECTION IN ACC ORDANCE WITH AC MA INS.
相互結線図
*6)2台または3 台接続可能。 6. 2 OR 3 SET S CAN BE CONNECTED .
SCALE MASS
NAME
終端のIC-3 07はジャンパー設定 の変更が必要。 CHANGE JUM PER SETTING IN LAS T IC-307.
IN MA RS AT- C ME S
CO-0.2x2P: CO -SPEVV-SB-C 0.2x2P, φ10.5
kg
*7)コネクタの 取り替えが必要。 7. REPLACE CO NNECTOR.
CO-0.2x5P: CO -SPEVV-SB-C 0.2x5P, φ13.5
DWG No.
IN TE RC ON NE CT IO N D IA GR AM
C 561 3-C0 1- J
FURUNO ELECTRIC CO., LTD.
NJ-8DFB-1
VCTF-1.25 x4C,3m,φ11.5
16S0042
VCTF-0.75x2C,3m ,φ7
05S0441
16S0083,0.2m
Dsub36P 1
プリ ンタ切替器
PRINT ER SWITCH
KSA-C E412L 3
Dsub36P 1
57FE-336-205W
5m
24VDC
R M12BPG-3S J1
アカ RED 1
+24V
クロ BLK 2
0V
シロ WHT 3
GND
献花(0)
+1
(本文系wangweiqin1...首藏)