IPC-TM-650 NumberSubjectDate 2.6.7ThermalShock&Continuity,PrintedBoard8/97 Revision A Table1 TestConditionATestConditionBTestConditionC StepTemperatureTimeTemperatureTimeTemperatureTime 10,+0/-515-40,+0/-515-55,+0/-515 225,+10/-5025,+10/-5025,+10/-50 3+70,+5/-015+85,+5/-015+105,+5/-015 425,+10/-5025,+10/-5025,+10/-50 TestConditionDTestConditionETestConditionF StepTemperatureTimeTemperatureTimeTemperatureTime 1-55,+0/-515-65,+0/-515-65,+0/-515 225,+10/-5025,+10/-5025,+10/-50 3+125,+5/-015+150,+5/-015+170,+5/-015 425,+10/-5025,+10/-5025,+10/-50 Toleranceshallbe+2and-0minutes. 6.1.1Unlessotherwisespecifiedbytheapplicableperfor- mancespecification,thefollowingbasematerialtypes/ temperatureratingsarerecommended. Table2 RigidTypeNEMATestCondition A GP,GT,GX,GYB GEC AF,BF,BI,CF,GF,GBD GH,GME AI,GI,QIF 6.2Suggestedsourcesforcapabletestequipment: CambridgeTechnology Model510AMicro-Ohmmeter 23ElmStreet Watertown,MA02172 (617)923-1181 Hewlett-Packard Model4338AMilliohmmeter 9800MuirlandsAvenue Irvine,CA92718 (714)472-3000 KeithlyInstruments Model580 Micro-ohmmeter 28775AuroraRoad Cleveland,OH44139 (800)552-1115 Page2of2 |
|