1.0ScopeThistestmethodisdesignedtodeterminethe

minimumandmaximumthicknessofthebasematerialof

metalliccladlaminatesbymicrosectioningandopticalmea-

surement.

2.0ApplicableDocuments

IPC-TM-650Method2.1.1,Microsectioning

IPC-TM-650Method2.2.18,DeterminationofThicknessof

Laminates,byMechanicalMeasurement

3.0TestSpecimens

3.1SizeUnlessotherwisespecified,aspecimenmeasuring

25.4X12.7mm[1.0X0.5in]shallbetakenfromthelaminate

sample.

3.2QuantityandSamplingUnlessotherwisespecified,

twosamplesshallbetakenfromthelotthatrepresentthe

centermostareaandtheedges,butnocloserthan25.4mm

[1.0in]fromtheedge,oftheas-manufacturedsheet.

4.0ApparatusorMaterial

4.1Anyopticalinspectionmeasuringdevicewithacapabil-

ityof100Xand200Xwithanaccuracyto0.0025mm[0.0001in].

4.2Amicrosectioningsystemcapableofpreparingspeci-

menmountsthatcanbeusedforthisprocedure.

5.0Procedure

5.1PreparationofSpecimensEachspecimentobe

measuredshallbemicrosectionedinaccordancewithIPC-

TM-650,Method2.1.1.Thelongdimensionofthespecimen

shallbeintheplaneofexamination.Specimensmaybe

gangedinaccordancewiththesamplingprocedure.

5.2EvaluationExaminetheentirelengthofthespecimen.

Determineandrecordtheminimumandmaximumthickness

ofeachspecimentothenearest0.0025mm[0.0001in]using

100XmagnificationandinaccordancewithFigures1or2,in

accordancewiththeapplicablespecification.Unlessother-

wisespecified,Figure2shallbeused.Anyrefereemeasure-

mentsshallbemadeat200Xmagnifications.

5.3ReportReporttheminimumandmaximumreadings

foundfromeachspecimeninspected,andwhethertheParal-

lel(Figure1)orRadius(Figure2)Methodwasused.

6.0NotesCross-sectionalthicknessrelatestotheeffective

electricalinsulationthicknessandwillusuallybelessthanthat

foundbymechanicalmeans(seeIPC-TM-650,method

2.2.18).Fordeterminationofthelaminate’scontributionto

overallboardthickness,themechanicalapproachispreferred

(whenmeasuringthincoresformultilayerapplications).

TheInstituteforInterconnectingandPackagingElectronicCircuits

2215SandersRoad?Northbrook,IL60062

IPC-TM-650

TESTMETHODSMANUAL

Number

2.2.18.1

Subject

DeterminationofThicknessofMetallicClad

Laminates,Cross-sectional

Date

12/94

Revision

OriginatingTaskGroup

MIL-P-13949TestMethodsTaskGroup(7-11b)

MaterialinthisTestMethodsManualwasvoluntarilyestablishedbyTechnicalCommitteesoftheIPC.Thismaterialisadvisoryonly

anditsuseoradaptationisentirelyvoluntary.IPCdisclaimsallliabilityofanykindastotheuse,application,oradaptationofthis

material.Usersarealsowhollyresponsibleforprotectingthemselvesagainstallclaimsorliabilitiesforpatentinfringement.

EquipmentreferencedisfortheconvenienceoftheuseranddoesnotimplyendorsementbytheIPC.

Page1of1