1.0ScopeThistestmethodisdesignedtodeterminethe
minimumandmaximumthicknessofthebasematerialof
metalliccladlaminatesbymicrosectioningandopticalmea-
surement.
2.0ApplicableDocuments
IPC-TM-650Method2.1.1,Microsectioning
IPC-TM-650Method2.2.18,DeterminationofThicknessof
Laminates,byMechanicalMeasurement
3.0TestSpecimens
3.1SizeUnlessotherwisespecified,aspecimenmeasuring
25.4X12.7mm[1.0X0.5in]shallbetakenfromthelaminate
sample.
3.2QuantityandSamplingUnlessotherwisespecified,
twosamplesshallbetakenfromthelotthatrepresentthe
centermostareaandtheedges,butnocloserthan25.4mm
[1.0in]fromtheedge,oftheas-manufacturedsheet.
4.0ApparatusorMaterial
4.1Anyopticalinspectionmeasuringdevicewithacapabil-
ityof100Xand200Xwithanaccuracyto0.0025mm[0.0001in].
4.2Amicrosectioningsystemcapableofpreparingspeci-
menmountsthatcanbeusedforthisprocedure.
5.0Procedure
5.1PreparationofSpecimensEachspecimentobe
measuredshallbemicrosectionedinaccordancewithIPC-
TM-650,Method2.1.1.Thelongdimensionofthespecimen
shallbeintheplaneofexamination.Specimensmaybe
gangedinaccordancewiththesamplingprocedure.
5.2EvaluationExaminetheentirelengthofthespecimen.
Determineandrecordtheminimumandmaximumthickness
ofeachspecimentothenearest0.0025mm[0.0001in]using
100XmagnificationandinaccordancewithFigures1or2,in
accordancewiththeapplicablespecification.Unlessother-
wisespecified,Figure2shallbeused.Anyrefereemeasure-
mentsshallbemadeat200Xmagnifications.
5.3ReportReporttheminimumandmaximumreadings
foundfromeachspecimeninspected,andwhethertheParal-
lel(Figure1)orRadius(Figure2)Methodwasused.
6.0NotesCross-sectionalthicknessrelatestotheeffective
electricalinsulationthicknessandwillusuallybelessthanthat
foundbymechanicalmeans(seeIPC-TM-650,method
2.2.18).Fordeterminationofthelaminate’scontributionto
overallboardthickness,themechanicalapproachispreferred
(whenmeasuringthincoresformultilayerapplications).
TheInstituteforInterconnectingandPackagingElectronicCircuits
2215SandersRoad?Northbrook,IL60062
IPC-TM-650
TESTMETHODSMANUAL
Number
2.2.18.1
Subject
DeterminationofThicknessofMetallicClad
Laminates,Cross-sectional
Date
12/94
Revision
OriginatingTaskGroup
MIL-P-13949TestMethodsTaskGroup(7-11b)
MaterialinthisTestMethodsManualwasvoluntarilyestablishedbyTechnicalCommitteesoftheIPC.Thismaterialisadvisoryonly
anditsuseoradaptationisentirelyvoluntary.IPCdisclaimsallliabilityofanykindastotheuse,application,oradaptationofthis
material.Usersarealsowhollyresponsibleforprotectingthemselvesagainstallclaimsorliabilitiesforpatentinfringement.
EquipmentreferencedisfortheconvenienceoftheuseranddoesnotimplyendorsementbytheIPC.