配色: 字号:
2_2_19_1 - length and width of laminate and preprep
2014-12-02 | 阅:  转:  |  分享 
  
1.0ScopeThismethodisdesignedtodeterminedimen-

sionalconformancetospecificationofproduction-cutpanels

oflaminateorprepregforlength,width,andperpendicularity.

2.0ApplicableDocuments

IPC-PC-90

3.0TestSpecimens

3.1SizeProductioncutpanelsinthedimensionsintended

forshipmentshallbeused.

3.2SamplingSamplingratesshallbeinaccordancewith

theapplicablespecification.(Alsosee6.1.)

4.0ApparatusorMaterialUnlessotherwisespecified,

precisionofmeasurementapparatusshallbeinaccordance

withtheapplicablespecification.

4.1Verniercaliperscapableofmeasuringupto914±6.4

mm[36.0±0.25in]orequivalent.

4.2Tapemeasurecapableofmeasuringupto1829mm

[72.0in]

4.3Carpenterssquare,orequivalent

4.4Pingauges,dialindicatorsorequivalent

5.0Procedure

5.1LengthMeasurethelengthoftheedgesofthepanel

thatareparalleltothegraindirectionusingaverniercaliper.

5.2WidthMeasurethelengthoftheedgesofthepanel

thatareperpendiculartothegraindirectionusingavernier

caliper.

5.3Perpendicularity

5.3.1MethodA:bydiagonals

5.3.1.1Measurethediagonalsofthepanelusingvernier

caliperortapemeasure.

5.3.1.2Calculateperpendicularityasfollows:

D=D1–D2(Maximumallowabledifferenceindiagonals)

Where:

D1

=√(L+T)

2

+W

2

D2

=√(L?T)

2

+W

2

L=Nominallengthofpanel[ins]

W=Nominalwidthofpanel[ins]

Tii=Toleranceininchesperinchforperpendicularity

shownintheprocurementdocument.

T=TiixW(Toleranceininches)

5.3.1.3Calculatetheactualdifferenceinthediagonalsfrom

themeasurementstaken.

5.3.1.4Comparetheactualdifferencetotheallowable

maximum.

5.3.2MethodB:Bycarpenterssquare(‘‘RightAngle’’

Square)

5.3.2.1Placethepanelinthecarpenterssquare,contacting

thesquarebyatleasttwocorners.

5.3.2.2Usingsuitablemeans(see4.4)measurethedis-

tanceofthepanel’scornerthatdoesnotcontactthesquare.

5.3.2.3Calculatetheperpendicularitybydividingthedis-

tancebythelengthofthelongestdimensionofthepanel.

5.4EvaluationComparethemeasurementswithdimen-

sionalrequirementsoftheapplicablespecification.Recordthe

numberofpanelsthatdonotcomply.Recordthenumberof

noncomplyingpanelsforeachdimension—length,width,and

perpendicularity.

5.5Reportthenumberofpanels,specifyingwhichdimen-

sion,thatdonotcomplywiththeapplicablespecification.

6.0Notes

6.1SamplingmayalsobedeterminedbyIPC-PC-90on

materialsproducedbycontinuousprocessing.

TheInstituteforInterconnectingandPackagingElectronicCircuits

2215SandersRoad?Northbrook,IL60062

IPC-TM-650

TESTMETHODSMANUAL

Number

2.2.19.1

Subject

Length,WidthandPerpendicularityofLaminate

andPrepregPanels

Date

12/94

Revision

OriginatingTaskGroup

MIL-P-13949TestMethodsTaskGroup(7-11b)

MaterialinthisTestMethodsManualwasvoluntarilyestablishedbyTechnicalCommitteesoftheIPC.Thismaterialisadvisoryonly

anditsuseoradaptationisentirelyvoluntary.IPCdisclaimsallliabilityofanykindastotheuse,application,oradaptationofthis

material.Usersarealsowhollyresponsibleforprotectingthemselvesagainstallclaimsorliabilitiesforpatentinfringement.

EquipmentreferencedisfortheconvenienceoftheuseranddoesnotimplyendorsementbytheIPC.

Page1of1

献花(0)
+1
(本文系安仁特化工首藏)