2 |
|
|
1.0ScopeThismethoddescribesatechniqueforevaluat-
ingamaterialtoresisttrackingwhensubjectedtoalowcur-
rentarcjustabovethesurfaceofthematerial.Itcanbeused
onmaterialsofvariousthicknessbystackingmaterials.This
procedureisbasedontechniquesdescribedinASTMD495.
2.0ApplicableDocuments
ASTMD495StandardTestMethodforHighVoltage,Low-
Current,DryArcResistanceofSolidElectrical
Insulation
Manufacturer’sInstructionManual
3.0TestSpecimens
3.1NumberThreespecimensshallbeusedunlessother-
wisespecified.
3.2FormEachspecimenshallbe3.0in.x2.0in.Material
under0.06in.inthicknessshallbebuiltuptoprovideaspeci-
menatleast0.06in.butnotexceeding0.125in.Forverythin
laminatesa1/16in.laminateofthesametypemaybeused
undertheactualspecimensubjectedtothearc,permittinga
reductionofthematerialrequiredwithoutsignificantlyaffecting
theresults.
3.3LocationSpecimensmaybecutfromanylocationina
sheet(exceptfromtheouter1in.offullsizesheets).
3.4FoilCladMaterialsAllfoilcladmaterialsshallhavethe
foilremovedbyetchingandshallbethoroughlycleanedprior
toconditioningortesting.
4.0Apparatus/Materials
4.1Arctester(BeckmanART-1
1
orequivalent,seeASTM
D495).
4.2Tungstenelectrodes(Beckman
2
orequivalent,see
ASTMD495).
4.3Constanttemperaturewaterbathcapableof50°C±
2°C,filledwithdistilledwater.
4.4Beakerorpanfilledwithambienttemperaturedistilled
water.
4.5Racksforsupportingspecimensinthewaterbathwith
allsurfacesexposed.
4.6Shear,saworpapercutterforcuttingspecimen.
4.7Alcoholorothersolventforcleaningelectrode.
4.8Crocuscloth.
4.9Gageblocksforcheckingelectrodespacing0.248in.
and0.252in.
4.10Lintfreepapertowels.
4.11Variac
3
autotransformertypeW1OMTorequivalent.
5.0Procedure
5.1PreconditioningUnlessotherwisespecifiedthespeci-
mensshallbeconditionedfor48hours(±2hours-0hours)in
distilledwatermaintainedat50°C±2°C.Followingthisstep
thespecimensshallbeimmersedinambienttemperaturedis-
tilledwaterfor30minutesminimum,4hoursmaximum,to
allowthemtoreachtemperatureequilibriumwithoutlossof
moisture.
5.2TestConditionsThetestshallberunatambienttem-
perature23°C±5°Candambienthumidity.
5.3Equipmentsetup
5.3.1Theelectrodeassemblyshallbecleanedthoroughly
usingalcoholorothersuitablesolventand,ifrequired,with
crocuscloth.Theelectrodegapshallbeadjustedifnecessary
toprovideagapof0.250in.±0.002in.whentheelectrodes
1.ART-1orART-2manufacturedbyBeckmanInstrumentsCedarGroveEssexCountyNewJersey,U.S.A.
2.ElectrodesmanufacturedbyBeckmanInstruments
3.VariacavailablefromGeneralRadio
TheInstituteforInterconnectingandPackagingElectronicCircuits
2215SandersRoad?Northbrook,IL60062
IPC-TM-650
TESTMETHODSMANUAL
Number
2.5.1
Subject
ArcResistanceofPrintedWiringMaterial
Date
5/86
Revision
B
OriginatingTaskGroup
N/A
MaterialinthisTestMethodsManualwasvoluntarilyestablishedbyTechnicalCommitteesoftheIPC.Thismaterialisadvisoryonly
anditsuseoradaptationisentirelyvoluntary.IPCdisclaimsallliabilityofanykindastotheuse,application,oradaptationofthis
material.Usersarealsowhollyresponsibleforprotectingthemselvesagainstallclaimsorliabilitiesforpatentinfringement.
EquipmentreferencedisfortheconvenienceoftheuseranddoesnotimplyendorsementbytheIPC.
Page1of2
restonthetestspecimen.
5.3.2Thearctestershouldbesetupforoperationinthe
automaticmode.
5.3.3SettheVariactothevoltagewhichproduces12,500
voltsbasedonthelastcalibrationoftheInstrument(generally
105Vto115V).
5.3.4Resetthetimeronthetesterto‘‘0’’secondsif
required.
5.4TestProcedure
5.4.1Removeapreconditionedspecimenfromtheambient
temperaturedistilledwaterandwipedrywithalintfreepaper
towel.
5,4.2Placeaspecimen(individualorbuiltup)intheelec-
trodefixture.
5.4.3Operatethetesterinaccordancewiththemanufactur-
er’sinstructionssuchthatanarcisgeneratedandautomati-
callyswitchedasindicatedbelow.
Time(sec)On/OffTimeAmperage
0-600.25sec/1.75sec10milliamps
60-1200.25sec/0.75sec10milliamps
120-1800.25sec/0.25sec10milliamps
180continuous10milliamps
5.4.4Observethearccarefullyand,atthepointwhichthe
arcdisappearsandtrackingoccurs,stopthetimerandrecord
thetimeforthespecimentothenearestsecond.
5.4.5Removethespecimen,removeandcleantheelec-
trodesthoroughlyusingasolventandifnecessarythecrocus
cloth.
5.4.6Replacetheelectrodeandchecktheelectrodegap.
5.4.7Resetthetimerandproceedasin5.4.1through5.4.6.
5.5Calculation
5.5.1Averagethevaluesofthespecimenstestedfromthe
samesampleandroundtothenearestsecond.
5.6Report
5.6.1Reporttheaveragevalueofthearcresistanceinsec-
onds.
5.6.2Reporttheambienttemperatureandrelativehumidity
atthetimeofthetest.
5.6.3Reporthowthespecimenwasprepared,e.g.indi-
vidual,#ofpliesbuiltup,orwithaspacer.
5.6.4Reportthepreconditioningprocedure.
5.6.5Reportanyanomaliesinthetestorvariationsfrom
proceduresortolerancesspecified.
6.0Note
6.1Theresultsofarctestsmaybesignificantlyaffectedby
contaminationoftheelectrodes.Anyirregularityofthearcin
theearlyportionofthetestmaybeanindicationofcontami-
nation.Ifthisoccurs,thetestshouldbestopped,theelec-
trodescleanedandafreshspecimenshouldbetested(orthe
testmayberuninadifferentareaofthesamespecimen).
6.2Whilevaluesforreinforcedmaterialmayvarywiththe
graindirectionofreinforcement,theeffectisgenerallyinsignifi-
cantwithglassreinforcedproduct.Atleastonespecimenin
bothmachineandtransversedirectionisrecommendedto
verifythis.
IPC-TM-650
Number
2.5.1
Subject
ArcResistanceofPrintedWiringMaterial
Date
5/86
Revision
B