HDBM-30/4cablefaultlocationpower
1.Generalintroduction
Itisadvancedequipmentascablefaultlocationpower.Thepulseoutputhas
twomode:singleoutput,andperiodicaloutput.
Function:
DCvoltagetest
Strongburningfunction,withinshorttimeitburnsbreakdownpoint,andlowers
resistanceatbreakdownpoint.
2.Technicaldata
outputvoltage(negative)0~30kVcontinuousregulation
Maximumburningpower:800W
Dischargecapacitor:4microfarad
Singledischargeenergy1800J
volume:42cm′42cm′80cm
Weight:90kg
workingpower220V±15%,1kVA
3.Operationinstruction
DCvoltagewithstand
Setfunctionswitchto“DChighvoltage”,andsetoutputDChighvoltage.
Singledischarge
Setfunctionswitchto“HVpulse”,modeas“single”andpress“pulsetriggering”
Andsystemwillmakesinglesetdischarge,breakdownthecablefault,and
formsabigcurrentpulse.
Periodicaldischarge
Functionswitchat“Highvoltagepulse”,modeas“period”,instrumentwill
dischargeperiodically.
Faulturgentstop
Duringtest,ifthereisnoabnormality,pressredbutton“switchoff”,and
instrumentwillturnoffpower,anddischargeautomaticallytoHVcapacitance
HDBM-30/4cablefaultlocationpower
andtestedobject.
Limitswitchfunction
Thereisstatusandpositioncheckatfunctionswitchpart.
HVcanstartonlywhenswitchispressed,andHVregulationbuttonisrotated
tobottomanti-clockwise.
4.supplyrange
4.1HDBM-30/4cablefaultlocationpower1set
4.2HVoutputcable1pc
4.3dischargerod1pc
4.4specialgroundingwire1pc
4.5powerwire1pc
4.6sparefuse(10A,6×30)2pcs
4.7usersmanual1pc
4.8certificate1set
4.9HDBM-30/4cablefaultlocationpowerusers’manual
5.Panel
5.1frontpanel
HDBM-30/4cablefaultlocationpower
HDBM-30/4frontpanel
Note:thepanelwillbeEnglishforforeigncustomer
NO1HVon;NO2currentmeter;NO3poweroff
NO4poweron;NO5voltmeter;NO6modeswitch
NO7pulsetrigger;NO8functionswitch;NO9HVregulationbutton
1.HVon:whenHVregulationbutton(No9)isbacktozero,andfunction
switch(NO8)ispressedatDChighvoltage,HVpulse,andstablearc,
pressHVswitch(NO1),andthenHVoutputpowerison,atthesametime,
HVonbuttonisoff,andpowerindicationlampon.
2.currentmeter:displayoutputcurrentwithrangeof100mA
3.poweroff:atemergency,pressthisbutton,andinnerworkpowerisoff,and
dischargedeviceautomaticallyconnectstoground.
4.poweron:whenkeyswitchisaton,poweronbuttonwilllight,pressthe
button,andworkpowerisconnected.
5.voltmeter:displayoutputvoltage,measurerangeis30kV.
6.modeswitch:workwithfunctionswitch,chooseHVoutputmode,singleor
HDBM-30/4cablefaultlocationpower
periodicalpulseoutput
7.pulsetrigger:whenmodeswitchedtosingle,presspulsetrigger,and
instrumentwilldischargeforonetime.Ittakesthreesecondstocharge
capacitor.Afterelectricityisfull,instrumentcantriggeragain.
8.functionswitch:therearefourgears,stablearc,lowvoltagepulse,DChigh
voltageandhighvoltagepulse.
9.HVregulationbutton:itregulatesoutputvoltage,andwithzerostart
function
5.2HDBM-30/4backpanel
Note:thepanelwillbeEnglishforforeigncustomer
1.Fusebase:innerΦ6×3010Afusetube
2.220VACpowersocket:outerconnectedwith220VACpower
3.Keyswitch
4.220VACpowersocket:whenconnectedwithHDTDRswitch.
5.Pulsecurrent:pulsecurrentcouplerinside,whosesignaloutputpulse
currentwaveform.
6.Stablearc:thesignaloutputwaveformofoutputarc.
6.Keyswitch
Atthebacksidethereisapowerswitch,whichcantakeitoffseparately.
7.Safety
7.1powerconnection
HDBM-30/4cablefaultlocationpower
Poweron④greenindicationlampgreenmeanspowerconnectionisOK.Plug
cablewire,andopenkeyswitchto“on”potion,andthenpoweron④islighting.
Ifitdoesnot,pleasecheckpowersocketorpowerline,whethertheycontacts
well.
7.2preparations
Presspoweron④,HVon①redlampon,connect220VACpower,andpower
off③doesnotlight.Atthistime,HVisnoton,andoutputisatshortcircuit
status.
7.3Starthighvoltage
PressHVon①,whenHVon①redlampisoff,poweroff③redlampison,
HVisstarted.Pleasenote:
Ifpresspoweroff③,andredlightofpoweroffisstillon,thatmean,HVisstill
effective.Pleasetakecarethatthereisstillhighvoltage.
7.4.safetyrequirement
Otherequipmentwhichisnotprotectedshallnotcontactwiththisequipment.
7.5safetyarea
Whentheequipmentisworkingthereshallbeaalarmingpanel,indicatingHV
danger.
7.6emergencyswitch
AtthebacksideofHDBM,thereisapoweroffemergencybutton.Ifthereis
anyabnormality,pressHVoff,andequipmentwillswitchoffpower.Auto
dischargedevicewillautomaticallydischargeHVandtestedobject,andmake
earthing.
8.Operationinstruction
8.1HDBMhasthreeoutputmodes:
DChighvoltage,HVpulseandstablearc(lowvoltagepulsewithstablearc).
Inalloutputmodes,voltageisoutputthroughHVcable,whichisputatthe
backpanel.Pleasenote,HVoutputcableinsertandoffshallbedonewhen
powerisnotconnected,andwhenthereisnovoltage(voltmeteris0.).The
HDBM-30/4cablefaultlocationpower
groundingshallbereliable.
HDBM-30/4HVoutputsocketandoutercovergroundingbase
8.2noticepoint
Beforeuseit,pleasemakesure:
Equipmentisreliablyconnectedtoearth
HVoutputcableandequipmentarereliablyconnected.
HVoutputcableandtestedobjectisreliablyconnected
Putalarmboardatthecablefarend,andmakeafenceoralarmingline.
8.3grounding
Beforeuseit,pleaseensurereliablegrounding.Theclipofgroundinglineshall
contactwithcleanmetal.Ifthereisrusty,pleaseclearitoff,andthenconnect
groundingwire.
8.4.HVoutputcableconnectionwithequipment
HVoutputcableoneterminalplugstoHVsocket,andtightthescrewonthe
socket.
HDBM-30/4cablefaultlocationpower
Redcliptocoaxialcablecore,blackclipandgroundingcliptoshieldinglayer
ofcoaxialcable.
8.5HVoutputcableandtestedcable.
Beforeconnection,takedischargerodtodischargethefaultcable,andthen
connectthefaultcabletogroundingwire,ensurethatfaultcableisfully
discharged,andthenstartwireconnection.
Cablecoreandshieldingfault:redcliptofaultcablecore,blackclipto
shielding,groundingcliptoearth.
Cablecoreandcorefault:redtocablecore,blackcliptoanotherphasecore,
andgroundingclipconnecttogroundreliably.
Coreandgroundfault:redtofaultcablecore,blackcliptoground,and
groundingcliptogroundreliably.
Coversafetygrounding:connectittogroundnearbytheequipment,tryto
makedistancefromredclipandgroundingclip.
Afterconnectionisover,takeoffthegroundingwireatfaultcable.
8.6functionswitchoperation
(a)functionswitchnormal(b)functionswitchfullyopen
Operation:raiseitathangingstatus,rotateittocorrespondingfunction,and
pressit.
8.7Dischargerod
HDBM-30/4cablefaultlocationpower
9.DChighvoltagetest
DCvoltagewithstandismainlyusedforresiduevoltage,DCvoltagewithstand
test,orburningpurposeafterloweringcablefaultpointresistance.
Operationindication:thepanelhasthreebuttons:pressthebuttonwhichis
lampon.
1.start,asto8.3,8.4,8.5.Takedischargerod,makethetestedobject
discharge.Connectagoodgroundingwiretotestedobject.Connectwell
theHVoutputwire,groundingwire,anddischargerod.
2.RotatethekeyswitchtoDChighvoltagegear,pressit.
3.Insertkey,rotateittoopen,andthenpoweronlamplights.
4.Presspoweron,greenlampisoff,HVonlights,andequipmentis
connectedtoworkpower.
5.Anti-clockwiseregulatethevoltagebutton,pressHVon,andHVonbuttonis
off.Powerofflampison.HVisstarted.
6.Accordingtotestrequirement,setoutputvoltage.Theequipmentdoesnot
haveovercurrentprotection.Testobjectbreakdowncauselowvoltageand
highcurrent.
7.Aftertestover,anticlockwiserotatethevoltagebuttontobottom,press
poweroff,switchoffpowerandequipmentautomaticallydischarge,andmake
grounding.Putthekeyswitchtooffposition,takeoffthekey,takeadischarge
rodtodischargethetestedobject,andthentakeoffHVoutputcable.
10.HVpulsetest
Forprelocationandpreciselocation,HVpulsedischargestofaultpoint.
HDBM-30/4cablefaultlocationpower
1.Start,asto8.3,8.4,8.5.Takedischargerod,makethetestedobject
discharged.Connectagoodgroundingwiretotestedobject.Connectwellthe
HVoutputwire,groundingwire,anddischargerod.
Aftercheck,takeoffthegroundingwireattestedobject,andgotonextstep.
2.Raisefunctionbutton,rotatetoHVpulsegear
3.Choosesingleorperiodical.Forprelocation,singleischosen.Forfault
preciselocation,chooseperiodicalmode.
4.Presspoweron,powerongreenlampisoff,andHVredlampison,and
equipmentispowered.
5.Rotatetheregulationbuttonanti-clockwisetobottom,pressHVon,andHV
onlampisoff,andthenHVison.
6.Accordingtotestrequirement,setoutputvoltage.Ifchoosesingle,press
|
|