平法梁配筋计算
集中标注表示:框架梁KL1,3跨,一端有悬挑,截面为300*600;箍筋为I级钢筋,直径8,加密区间距为100,非加密区间距为200 ,均为两肢箍;上部通长筋为2根直径22的二级钢; 原位标注表示:支座1上部纵筋为4根直径22的二级钢,支座2两边上部纵筋为6根直径22的二级钢分两排,上一排为4根,下一排为2根;第一跨跨距3600,下部纵筋为3根直径18的二级钢,全部伸入支座,;第二跨跨距5800,下部纵筋为4根直径18的二级钢,全部伸入支座;以后类推。 1. Lae:纵向受拉钢筋抗震锚固长度(任何情况下不得小于250mm)
Ln: 梁净跨; Hc: 柱截面沿框架方向的高度 2. 一级抗震加密区>=2Hb,二至四级>=1.5Hb 上部通长筋2b22: L=各跨长之和+悬梁跨长+左支座左半宽-2*BHC+max(Lae-支座宽+BHC,15d)+12d =3600+5800+3600+2800+200-2*25+35*22-400+25+12*22 =15950+395+264 支座1右端上部一排筋2b22: L=Ln/3(Ln为净跨值)+支座宽-BHC+ max(Lae-支座宽+BHC,15d) = (3600-200*2)/3+400-25+35*22-400+25 =1442+395 支座2两端上部一排筋2b22: L=Ln(支座两边较大一跨的净跨值)/3+支座+Ln/3 = (5800-200*2)/3+400+ (5800-200*2)/3 = 4000 支座2两端上部二排筋2b22: L=Ln(支座两边较大一跨的净跨值)/4+支座+Ln/4 =(5800-200*2)/4+400+(5800-200*2)/4 =3100 支座3两端上部一排筋2b22: L=Ln(支座两边较大一跨的净跨值)/3+支座+Ln/3 = (5800-200*2)/3+400+ (5800-200*2)/3 = 4000 支座3两端上部二排筋2b22: L=Ln(支座两边较大一跨的净跨值)/4+支座+Ln/4 =(5800-200*2)/4+400+(5800-200*2)/4 =3100 支座4两端上部一排筋2b22: L=Ln/3(Ln为净跨值)+支座宽+悬梁长-BHC = (3600-200*2)/3+400+2800-200-25 = 4042 第一跨下部纵筋3b18: L=Ln+支座宽-BHC+max(Lae,0.5Hc+5d) +max(15d, Lae-支座宽+BHC) =3600-2*200+400-25+35*18+ 15*18 =4205+270 第二跨下部纵筋4b18: L=Ln+max(Lae,0.5Hc+5d)*2 =(5800-200*2)+2*35*18 =6660 第三跨下部纵筋3b18: L= Ln+max(Lae,0.5Hc+5d)*2 =(3600-2*200)+2*35*18 =4460 右悬梁下部筋3b18: L= 悬梁长-BHC+15d =(2800-200)-25+15*18 =2845 箍筋尺寸: L1=300-2*25+2*8=266 L2=600-2*25+2*8=566 第一跨箍筋根数: N=2*Round(1.5Hb-50)/间距+Round(Ln-2*1.5*Hb)/间距+1 =2*Round[(1.5*600-50)/100]+Round[(3600-400-2*1.5*600)/200]+1 =2*9+7+1=26根 第二跨箍筋根数: N=2*Round[(1.5*600-50)/100]+[Round(5800-400-2*1.5*600)/200]+1 =2*9+18+1=37根 第三跨箍筋根数:(同第一跨 ) N=26根 右悬梁箍筋根数: N=Round[(2800-200-2*50)/100] +1 =26根 总根数:N=26+37+26+26=115根 平法柱配筋计算 柱钢筋主要分为纵筋和箍筋。 柱纵筋分角筋、截面b边中部筋和h边中部筋;相邻柱纵向钢筋连接接头要相互错开;在同一截面内钢筋接头面积百分率不应大于50%;柱纵筋连接方式包括绑扎搭接、机械连接和焊接连接。 柱箍筋按钢筋级别、直径、间距注写,当为抗震时用斜线“/” 区分柱端箍筋加密区与柱身非加密区内箍筋不同间距。如柱全高 为一种间距时则不用“/”;圆柱采用螺旋箍筋时需在箍筋前加“L”。 基础部分 6b25: L1=底部弯折+基础高+基础顶面到上层接头的距离(满足>=Hn/3) =200+(1000-100)+(3200-500)/3 =200+1800 6b25: L2=底部弯折+基础高+基础顶面到上层接头的距离+纵筋交错距离 =200+(1000-100)+(3200-500)/3+Max(35d,500) =200+2675 一层: 12b25: L1=L2=层高-基础顶面距接头距离+上层楼面距接头距离 =3200-Hn/3+Max(Hn/6,Hc,500) =3200-900+550 =2850 二层: 12b25: L1=L2=层高-本层楼面距接头距离+上层楼面距接头距离 =3200-Max(Hn/6,Hc,500)+Max(Hn/6,Hc,500) =3200-550+550 =3200 三层: 12b25: L1=L2=层高-本层楼面距接头距离+上层楼面距接头距离 =3200-Max(Hn/6,Hc,500)+Max(Hn/6,Hc,500) =3200-550+550 =3200 顶层:柱外侧纵筋4b25:2b25: L1=层高-本层楼面距接头距离-梁高+柱头部分 =3200-Max(Hn/6,Hc,500)-500 + Hb-BHC +1.5Lae-(Hb-BHC)) =3200 –550-500+ (500-30)+1.5*35*25-(500-30) =2620+843 2b25: L2=层高-(本层楼面距接头距离+本层相邻纵筋交错距离) -梁高+柱头 =3200-(Max(Hn/6,Hc,500) +Max(35d,500))-500+Hb-BHC +1.5Lae-(Hb-BHC)) =3200-(550+35*25)-500+(500-30)+1.5*35*25-(500-30) =1745 +843 柱内侧纵筋8b25: 4b25: L1=层高-本层楼面距接头距离-梁高+柱头部分 =3200-Max(Hn/6,Hc,500)-500 + Hb-BHC +12d =3200-550-500 +500-30+12*25 =2620+300 4b25: L2=层高-(本层楼面距接头距离+本层相邻纵筋交错距离) -梁高+柱头 =3200-(Max(Hn/6,Hc,500) +Max(35d,500))-500 + Hb-BHC +12d =3200-(550+35*25)-500+(500-30)+12*25 =1745 +300 箍筋尺寸: B边 550-2*30+2*8=506 H边 550-2*30+2*8=506 箍筋根数: 一层:加密区长度 = Hn/3+Hb+max(柱长边尺寸,Hn/6,500) =(3200-500)/3+500+550=1950 非加密区长度=Hn- 加密区长度=(3200-500)-1950=750 N=Round(1950/100)+Round(750/200)+1=25 二层:加密区长度 =2*max(柱长边尺寸,Hn/6,500) +Hb =2*550+500=1600 非加密区长度=Hn- 加密区长度=(3200-500)-1600=1100 N=Round(1600/100)+Round(1100/200)+1=23 三、四层同二层 总根数:N=2+25+23*3=96根 平法剪力墙配筋计算 剪力墙身表达形式为Qxx(x排),括号内为墙身所配置的水平钢筋与竖向钢筋的排数(排数的规定见平法03G101-1第13页)。
剪力墙身共有三种钢筋,水平钢筋、竖向钢筋和拉筋 。端柱、小墙肢的竖向钢筋构造与框架柱相同,水平钢筋的计算比较简单,拉筋尺寸及根数要依据具体设计来进行计算。 下面就以一个实例来计算墙的配筋: 基础部分纵筋: b12 L =基础内弯折+基础内高度+搭接长度Lle = 240+(1200-100)+1.6*Lae =240+(1200-100)+1.6*35*12 =240+1772 根数:N=排数*[Round(墙净长-50*2/间距)+1] =2*[ Round (5200-50*2/200)+1] =2*27 =54 中间层: 一层:竖向钢筋:L =层高+上面搭接长度 Lle = 3200+1.6*Lae =3200+1.6*35*12 =3872 根数: N=排数*[Round(墙净长-50*2/间距)+1] =2*[ Round (5200-50*2/200)+1] =2*27 =54 一层:水平钢筋:L =左端柱长度-保护层+墙净长+左端柱长度-保护层+2*弯折 = (400-15)+5200+(400-15)+2*15d =5970+2*15*12 =5970+180+180 根数: N=排数*(墙净高/间距+1) =2*[(3200-100)/200+1)] =2*17 =34 一层:拉筋:L =墙厚-2*保护层厚度+2*直径 = 300-2*15+2*6 =282 根数: N=墙高/间距*墙净长/间距 =(3200-100)/200*(5200/200) = 416 二层同一层 顶层:竖向钢筋: L =层高-保护层+(Lae-板厚+保护层) = 3200-15+(35*12-100+15) =3185+335 根数同中间层: N=54 水平筋和拉筋同中间层 THE END |
|